Installation
2841 E. Industrial Drive  Springfield, MO  65802-6310  800-641-4282
XR10/XR20 Installation Guide
Annunciator Outputs
12.1 Description
The four annunciator outputs can be programmed to indicate the activity of the panel's zones or conditions
occurring on the system. Annunciator outputs do not provide a voltage but instead switch to ground
voltage from another source.
 The outputs can respond to any of the conditions listed below:
1)  Activation by zone condition: Steady, Pulse, Momentary, or Follower
2)  Manually from the Security Command keypad
3)  Communication failure
4)  Armed area annunciation
5)  Fire Alarm or Fire Trouble
7)  Ambush alarm
8)  Exit and Entry timers
9)  System Ready
10)  Ground start activation
12.2 Harness wiring
The open collector outputs are accessible by installing the DMP 300 Harness on the 4-pin header labeled J11.
The output locations are shown below:
Output
Color
  Wire
1
Red
1
2
Yellow
2
3
Green
3
4
Black
4
Devices connected to the outputs must be located within the same room as the XR10/XR20 panel.
Telephone RJ Connector
13.1 Description
Connect the panel to the public telephone network by installing a DMP 356 RJ Cable between the panel's J4
connector and the RJ31X or RJ38X phone jack.
13.2 FCC registration
The Model XR10/XR20 complies with FCC part 68 and is registered with  the FCC.
Registration number: CCKUSA - 18660 - AL - R
Ringer Equivalence: 1.1B
13.3 Notification
Registered terminal equipment must not be repaired by the user. In case of trouble, the device must be
immediately unplugged from the telephone jack. The factory warranty provides for repairs.  Registered terminal
equipment may not be used on party lines or in connection with coin telephones. Notification must be given to
the telephone company of:
a. The particular line(s) the service is connected to
b. The FCC registration number
c. The ringer equivalence
d. The make, model, and serial number of the device