DATA SHEET
 
TEST LEVEL CODES
 
All electrical characteristics are subject to the following conditions:
All parameters having min/max specifications are guaranteed. The Test Level column indicates the specific device testing
actually performed during production and Quality Assurance inspection.
 
LEVEL TEST 
PROCEDURE
 
100% production tested at the specified temperature.
IV 
Parameter is guaranteed by design or characterization data.
Parameter is a typical value for information purposes only.
 
Power Supply Requirements
 
Supply Voltage
AV
 
DD
 
 = DV
 
DD
 
IV
3.0
+3.3
3.6
V
Supply Current Sleep Mode
AV
 
DD
 
25MHz Clock
V
9.5
mA
DV
 
DD
 
25MHz Clock
V
200
 
µ
 
A
Power Dissipation
20mA I
 
OUT
 
IV
170
195
215
mW
12mA I
 
OUT
 
V
149
mW
 
Parameter
Conditions
Test Level
Min
Typ
Max
Units
 
Electrical Specifications 
 
(Continued)
 
(
 
T
 
A
 
 = 25°C, AV
 
DD
 
 = 3.3V, DV
 
DD
 
 = 3.3V, 
 
ƒ
 
OUT
 
 = 1.27MHz, 
 
ƒ
 
CLK
 
 = 400MHz, Clock Duty Cycle = 50%, 
I
 
OUT
 
 = 20mA, R
 
L
 
 = 50
 
Ω
 