Sterling 882.000254.00 User Manual
7/50D Plus or 7/50D Controller
Chapter 4: Operation
56
The following table explains the status represented by each color at the Station Summary
screen.
screen.
Color Label
Description
Gray outline
Offline
Station is not enabled. The controller ignores any demands or
alarms.
alarms.
Blue
Ready
Station is enabled and idle (full).
Yellow
Demand
Station requires material.
Green
Loading
Station is being loaded with material or is dumping material into
its receiver.
its receiver.
White
Purging
The material line is being purged of material.
Light Blue
Dumping
The station is dumping material into its receiver.
Blue, blinking
Blow Back
Station’s air filter is being cleaned by blowing compressed air
backward through it.
backward through it.
Black, blinking
Bypass
Bypass switch at the station has been turned on, disabling the
station.
station.
Green, blinking
Priority
Station is in priority convey mode. Its pump will be temporarily
dedicated to filling it as soon as possible.
dedicated to filling it as soon as possible.
Red, blinking
Alarm
Station is in alarm.
Red outline, blinking
Critical
Station is in critical alarm. The controller has disabled the station
until the alarm is cleared.
until the alarm is cleared.
Additional basic information about each station (convey time, dump delay, pump assignment,
and, if enabled, RPV setting, purge settings, and material proofing) is available at the Station
n Operator screen. See p. 61 for details.
and, if enabled, RPV setting, purge settings, and material proofing) is available at the Station
n Operator screen. See p. 61 for details.
Detailed configuration settings for each station are available at the Station n Setup screen. See
p. 74 for details.
p. 74 for details.