If current channel is recording now, the setup will get activated immediately, 
and the current record will be terminated and a new file is created as 
redundancy recording is started.  
After setup is completed, please click save button, system goes back to the 
previous menu. 
Search and playback of the records in the redundant disk. 
In Search, input search conditions and click Redundancy Search, and the 
records on the redundancy disk will be listed and can be played.  
Detect 
Go to Detect Menu  
In the main menu, from Setting to Detect, you can see motion detect 
interface. There are three detection types: motion detection, video loss, 
camera masking. 
Motion Detection 
The detection menu is shown as below. See 
  Event type: From the drop-down list you can select the “Motion 
Detection” type. 
  Channel: Select the video channel for the motion detection setting. 
  Record Channel: Select the channel to activate the recording function 
once the alarm has  sounded. Please make sure you have set the MD 
recording in the schedule interface (Main MenuSettingSchedule
and automatic recording in manual record interface (Main Menu-
>Advanced->Manual Record)  
  Delay: When detected motion is completed, the system will continue 
alarm output and recording for a specified time respectively. The value 
ranges from 10-300(Unit: second). 
 Region: 
Click 
Select, the interface is shown as in 
. Here 
you can set the motion detection zone. There are 396(PAL)/330(NTSC) 
small zones. 
  Sensitivity: The system supports 6 levels. The sixth level has the 
highest sensitivity. The fifth or lower levels are recommended to avoid 
setting a false alarm.