7 -  5
7. SPECIAL ADJUSTMENT FUNCTIONS
7.5 Gain changing function
This function can change the gains. You can change between gains during rotation and gains during stop
or can use an external signal to change gains during operation.
7.5.1 Applications
This function is used when.
(1) You want to increase the gains during servo lock but decrease the gains to reduce noise during rotation.
(2) You want to increase the gains during settling to shorten the stop settling time.
(3) You want to change the gains using an external signal to ensure stability of the servo system since the
load inertia moment ratio varies greatly during a stop (e.g. a large load is mounted on a carrier).
7.5.2 Function block diagram
The valid control gains PG2, VG2, VIC and GD2 of the actual loop are changed according to the conditions
selected by gain changing selection CDP (parameter No. 49) and gain changing condition CDS (parameter
No. 50).
Valid 
GD2 value
Command pulse 
frequency
Droop pulses
Model speed
Control command 
of controller
Comparator
Valid 
PG2 value
Valid 
VG2 value
Valid 
VIC value
Changing
PG2    PG2B
100
VIC    VICB
100
VG2    VG2B
100
GD2B
Parameter No.52
GD2
Parameter No.12 
PG2
Parameter No.15
VG2
Parameter No.16
VIC
Parameter No.17
CDP
Parameter No.49
CDS
Parameter No.50