3com V7111 User Manual

Page of 71
 
To change the default gateway IP address, press 3 followed by the # key. 
ƒ
  The current default gateway address of the gateway is played. Press # to change it. 
ƒ
  Dial the new default gateway address; e.g. 192*168*0*1 and press # to finish. 
ƒ
  Review the new default gateway address, and press 1 to save it. 
Hang up the handset. Access the gateway's Embedded Web Server with the new IP 
address you assigned (see 
). 
Reset the gateway. Click the Reset Device button on the main menu bar; the Reset 
screen is displayed. Click the button Reset (with the Burn option selected). 
Assigning an IP Address Using the CLI 
First access the CLI using a standard Telnet application or using a serial communication 
software (e.g., HyperTerminal
TM
) connected to the V7111 RS-232 port (see 
). 
Then assign the V7111 an IP address (see 
). 
Access the CLI 
To access the CLI via the Embedded Telnet Server, follow these 3 steps: 
Enable the Embedded Telnet Server: 
ƒ
  Access the V7111 Embedded Web Server (see 
). 
ƒ
  Set the parameter ‘Embedded Telnet Server’ (under Advanced Configuration 
Network Settings 
Application Settings) to ‘Enable (Unsecured)’ or ‘Enable 
Secured (SSL)’. 
ƒ
 Click 
the 
Reset Device
 button on the main menu bar; the Reset screen is displayed. 
ƒ
 Click 
the 
Reset
 button in the middle of the Reset screen with the Burn option 
selected; the V7111 is shut down and re-activated. A message about the waiting 
period is displayed. The screen is refreshed. 
Use a standard Telnet application to connect to the V7111 Embedded Telnet Server. 
Note that if the Telnet server is set to SSL mode, a special Telnet client is required on 
your PC to connect to the Telnet interface over a secured connection. 
Login using the username (‘Admin’) and password (‘Admin’). 
To access the CLI via the RS-232 port, follow these 2 steps: 
Connect the RS-232 port to your PC (For the V7111, see 
 For the V7111 24-
). 
3Com VCX V7111 Analog Gateway Installation Guide 
 29