Troubleshooting
Motor & Electrical
Symptom
Possible Cause
Possible Solution
Machine  does  not 
start  or  a  breaker 
trips.
1.  Fuse has blown.
2.  Emergency  stop  push-button  is  engaged/
faulty.
3.  Hand-held remote controller is at fault.
4.  Receiver is at fault.
5.  Motor connection wired incorrectly.
6.  Wall fuse/circuit breaker is blown/tripped.
7.  Thermal overload relay has tripped.
8.  Contactor  not  getting  energized/has  burnt 
contacts.
9.  Power supply switched OFF or is at fault.
10. Wiring is open/has high resistance.
11. Motor  ON  button  or  ON/OFF  switch  is  at 
fault.
12. Emergency stop push-panel is stuck/switch 
is at fault.
13. Transformer is at fault.
14. Computer board is at fault.
15. Inverter/control box is at fault.
16. Motor is at fault.
17. Start delay module is at fault.
1.  Correct short/replace fuse in control box.
2.  Rotate clockwise slightly until it pops out/replace it.
3.  Replace  batteries  in  hand-held  remote  controller; 
stay in line-of-sight view and signal range.
4.  Inspect receiver computer board; replace if faulty.
5.  Correct motor wiring connections (
Pages 46 & 49).
6.  Ensure  circuit  size  is  suitable  for  this  machine; 
replace weak breaker.
7.  Turn cut-out dial to increase working amps and push 
the reset pin. Replace if tripped multiple times (weak 
relay).
8.  Test for power on all legs and contactor operation. 
Replace unit if faulty.
9.  Ensure power supply is switched on; ensure power 
supply has the correct voltage.
10. Check  for  broken  wires  or  disconnected/corroded 
connections, and repair/replace as necessary. 
11. Replace faulty ON button or ON/OFF switch.
12. Free push-panel from binding; replace faulty switch.
13. Replace  transformer.  Refer  to 
Page  12  for  more 
detail information.
14. Inspect computer board; replace if faulty.
15. Inspect inverter/control box; replace if faulty.
16. Test/repair/replace.
17. Adjust to correct delay; replace module.
Machine  has  vibra-
tion  or  noisy  opera-
tion.
1.  Motor or component is loose.
2.  Motor mount loose/broken.
3.  Machine  is  incorrectly  mounted  or  sits 
unevenly.
4.  Motor fan is rubbing on fan cover.
5.  Motor bearings are at fault.
1.  Inspect/replace stripped or damaged bolts/nuts, and 
re-tighten with thread locking fluid.
2.  Tighten/replace.
3.  Tighten/replace anchor studs in floor; relocate/shim 
machine.
4.  Replace  dented  fan  cover;  replace  loose/damaged 
fan.
5.  Test by rotating shaft; rotational grinding/loose shaft 
requires bearing replacement.