Programming the DBS
1.  Enter the DBS programming mode
2.  Set the API port to Telephony Services as follows:.
Note: The Telephony Services NLM defaults to use the first port (41). 
3.  Set the Telephony Services API Port Baud rate to the desired baud rate as 
follows:.
Note: If Telephony Services is the only connection to the API card, it is 
recommended that the baud rate be set to19200. If both API ports are 
used, it is recommended that both baud rates be set to 9600 bps.
Program 
Name
API Port Type
Address
FF1 2# 1# (41 or 42)# 1# (0-1)#
Program 
Name
API Baud Rate
Address
FF1 2# 1# (41 or 42)# 2# (0-1)#
API Port Number  
41 = Port 1
42 = Port 2
Port Type:
1 = Telephony Services protocol
0 = Standard API protocol (default)
Baud Rate:
1 = 19200
0 = 9600 (default)
API Port Number  
41 = Port 1