808A Emergency Transfer Panel and telephone installation examples
Issue 3 January 2008
101
.
Table 17: Trunk/test switches
Switch
number
number
Circuit
number
number
1
1
2
1
3
2
4
2
5
3
6
3
7
4
8
4
9
5
10
5
11
Not Used
12
Test Switch
Table 18: Pin assignments for 25-pair connector
26
W-BL
TTC1
Tip-PBX Trunk Circuit 1
1
BL-W
RTC1
Ring-PBX Trunk Circuit 1
27
W-O
TTK1
Tip-CO Trunk Circuit 1
2
O-W
RTK1
Ring-CO Trunk Circuit 1
28
W-G
TLC1
Tip-PBX Line Port 1
3
G-W
RLC1
Ring-PBX Line Port 1
29
W-BR
TST1
Tip-Emergency Terminal 1
4
BR-W
RST1
Ring-Emergency Terminal 1
30
W-S
TTC2
Tip-PBX Trunk Circuit 2
5
S-W
RTC2
Ring-PBX Trunk Circuit 2
31
R-BL
TTK2
Tip-CO Trunk Circuit 2
6
BL-R
RTK2
Ring-CO Trunk Circuit 2
1 of 3