808A Emergency Transfer Panel and telephone installation examples
Issue 3 January 2008
99
 
Figure 48: 808A Emergency Transfer Panel mounting
Installing the 808A Emergency Transfer Panel 
Note:
Note:
The 808A must be installed in a location that can be accessed only by authorized 
personnel. The location must meet standard environmental considerations such 
as temperature, humidity, and so forth.
To install the 808A Emergency Transfer Panel:
1. Verify dial tone is present at each trunk circuit.
2. Locate the circuit start selection switches (see 
These are the first 10 two-position switches on the left side of the Emergency Transfer 
Panel. They are used to set each of the five incoming trunk lines to either loop start or 
ground start. Two switches are used for each circuit; switches 1 and 2 are used for circuit 1, 
switches 3 and 4 are used for circuit 2, and so forth. See 
3. For loop start, set the switches to the left. For ground start, set the switches to the right.
Figure notes:
1. 808A Emergency Transfer Panel
2. Ear for Screw Mount
3. Cut-Out for Snap Mount
4. 25-Pair Male Connector
5. Circuit Start Switches
808a_em LJK 042396