Pelco C2900M-B(1/03 User Manual

Page of 112
C2900M-B (1/03)
59
Receiver email
empty
If applicable, enter the e-mail address where you
address
want an e-mail sent in the event of an alarm.
Idle state
open
You can configure the switching behavior of each
built-in relay output at idle: open (N.O. at zero
current) or closed (N.C. at zero current).
Operating mode
Bistable
Select an operating mode for each relay.
• When you select the default Bistable mode, the
relay will stay in the idle or active state for an
indefinite period. (For example, select Bistable if
a floodlight activated by an alarm is to remain
switched on at the end of the alarm.)
• When you select Monostable mode, the relay
automatically falls back to the idle state after a
predefined period expires. (For example, select
Monostable 10s if a siren triggered by an alarm is
to sound for a period of 10 seconds.)
Relay follows
None
If necessary, select a particular event from the pull-
down menu that will trigger the relay. A typical
application is having the relay following the status of
the connection; for example, to power peripheral
equipment or even the camera itself. Select from the
following:
• Motion alarm: Triggering by motion alarm
• Input pin: Triggering by external alarm sensor
• Video loss: Triggering by video signal alarm
• Connection: Triggering at each connection setup
• Remote input pin: Triggering by switching
contact of the remote station
• None: No relay triggering by events
Relay Names
Relay 1-4
Assign a relay name to each output.
Trigger Relay
n/a
Clicking the appropriate Relay button switches that
relay by hand. Typical applications are opening
remote doors or operating lights.
Table F.  Alarm Settings (Continued)