B&B Electronics ESP902E User Manual

Page of 47
 RS-422 
Connections 
Manual Documentation Number: ESP901-902-3704 
Appendix B 
75 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com 
A
A
P
P
P
P
E
E
N
N
D
D
I
I
X
X
 
 
B
B
:
:
 
 
R
R
S
S
-
-
4
4
2
2
2
2
 
 
C
C
O
O
N
N
N
N
E
E
C
C
T
T
I
I
O
O
N
N
S
S
 
 
Serial Server DB-9 Pin-outs in RS-422 Mode 
 
RS-422 
Signal Name 
 
Direction 
 
RS-422 
DB9M 
Pin 
Receive Data A (−) In 
RXDA 
(−) 1 
Receive Data B (+) 
In 
RXDB (+) 
Transmit Data B (+) 
Out 
TXDB (+) 
Transmit Data A (−) Out 
TXDA 
(−) 4 
Signal Ground 
--- 
GND 
Clear to Send A (−) In 
CTSA 
(−) 6 
Clear to Send B (+) 
In 
CTSB (+) 
Request to Send B (+) 
Out 
RTSB (+) 
Request to Send A (−) Out 
RTSA 
(−) 9 
Figure 66. 
RS-422 Connections in a DB-9 Connector 
 
 
 
 
RS-422 Connections 
76 
Appendix B 
Manual Documentation Number: ESP901-902-3704 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com 
 
Figure 67.  RS-422 Connections with Flow Control 
In the RS-422 mode, TXD lines are outputs and RXD lines are inputs. 
Connect the 
Serial Server
 TXDB(+) line to the RXDB(+) line of the 
serial device, and the 
Serial Server
 TXDA(-) to the RXDA(-) of the 
serial device. 
If Flow Control is set for RTS/CTS, connect the 
Serial Server
 
RTSB(+) to CTSB(+) of the serial device and the 
Serial Server
 
RTSA(-) line to the CTSA(-) of the serial device. Connect from the 
Serial Server
 CTSB(+) line to the RTSB(+) of the serial device and 
from the 
Serial Server
 CTSA(-) line to the RTSB(+) line of the serial 
device. 
If connecting to Receive Only RS-422 devices, connect from the 
Serial Server
 TXDB(+) and TXDA(-) lines to the receive pairs on all 
serial devices. 
Ground is signal ground and provides a common mode reference for 
the RS-422 Receiver and Transmitters. 
N
N
o
o
t
t
e
e
:
:
 
 
 
The RS-422 mode can be used for full duplex 4-wire RS-485 operation 
provided that the serial server is acting as a sole master connecting to 
all the slave devices, and all slave devices share the Receive signal 
lines to the master. Set Flow Control for none, and omit connections to 
RTS/CTS line pairs. 
Serial Server pin-out 
in RS-422 mode 
 RS-422 
 
Device 
RS-422 Signal Names 
DB-9 
Pin# 
Connections
Signal 
Receive A (-) 
RXDA(-) 
 
TDA(-) 
Receive B (+) 
RXDB(+) 
 
TDB(+) 
Transmit B (+) 
TXDB(+) 
 
RDB(+) 
Transmit A (-) 
TXDA(-) 
 
RDA(-) 
Ground GND 
  GND 
Clear to Send A (-) 
CTSA(-) 
 
RTSA(-) 
Clear to Send B (+) 
CTSB(+) 
 
RTSB(+)
Ready to Send B (+)  RTSB(+) 
 
CTSB(+)
Ready to Send A (-) 
RTSA(-) 
 
CTSA(-)