Serial Server DB-9 Pin-out in RS-485 Mode 
 
RS-485 
Signal Name 
Direction RS-485 DB9M 
Pin 
Data B (+) 
In/Out 
DATA B (+) 
Data A (−) 
In/Out 
DATA A (−) 4 
Signal Ground 
--- 
GND 
Figure 70. 
DB-9 Pin-out in RS-485 Mode 
N
N
o
o
t
t
e
e
:
:
 
 
 
 
Some RS-485 devices are marked opposite the RS-485 standard, 
which defines the Data B line as positive relative to Data A during a 
Mark state before enabling the transmitter, and after transmitting 
before tri-stating. If an RS-485 device does not respond, try swapping 
the Data B and Data A lines.  
 
Figure 71.  2-wire RS-485 Connection 
To connect 4-Wire RS-485 devices, the RS-422 Mode can be used 
provided the 
Serial Server
 will be connected as a master in a single 
master system. If using multiple masters, the 
Serial Server
 cannot be 
used, as it does not tri-state the transmitter in RS-422 mode. 