Avaya S8100 User Manual

Page of 408
1
Install and cable a G600 cabinet
Install and wire telephones and other equipment
S8100 Installation and Upgrades
107
November 2003
Figure 30: Example adjunct power connections
Local and phantom power
The attendant console’s (AC’c) maximum distance from the system is limited. 
See 
Figure notes
1
Typical display telephone
2
Individual power supply (such as 
1151B, not used if item 14 is used)
3
400B2 adapter
4
Information outlet (modular jack)
5
4-pair D-Inside Wire (DIW) cable
6
Satellite site or adapter location
7
25-pair D-Inside Wire (DIW) cable
8
Station side of MDF or patch panel
9
100P6A patch cord or jumpers
10
System side of MDF or patch panel
11
25-pair cable to Digital Line circuit pack
12
Equipment room
13
Satellite location
14
Bulk power supply (such as 1145B). Install at 
satellite location or equipment room (not both).
Table 12: Attendant console cabling distances
Enhanced attendant 
console (302C1)
24 AWG wire (0.26 mm
2
)
26 AWG wire (0.14 mm
2
)
Feet
Meters
Feet Meters
With selector console
Phantom powered
800
244
500
152
Locally powered
5000
1524
3400
1037
Without selector console
Phantom powered
1400
427
900
274
Locally powered
5000
1524
3400
1037
cydmapwr EWS 052898
1
2
3
4
5
6
7
8
9
10
11
12
13
14
14