Avaya S8100 User Manual

Page of 408
1
Install and cable a G600 cabinet
Install and wire telephones and other equipment
S8100 Installation and Upgrades
111
November 2003
Connect the cables
Every port on the front of the 1152A1 PDU is configured as a data route-through port for every data wire 
(pins 1, 2, 3, and 6).
Use a standard CAT5, CAT6, or CAT6e straight-through Ethernet cable (not supplied), including all 
8 wires (4 pairs) as shown in 
Figure 31: Connecting telephones and other end devices to the 1152A1 PDU 
For Data-In ports connect the Ethernet cable leading from the Ethernet Switch/Hub to the Data port. For 
Data & Power Out ports connect the Ethernet cable leading to the telephone or other end device to the 
corresponding Data & Power port.
NOTE:
Be certain to connect correspondingly numbered Data and Data & Power ports.
Connecting cables to telephones and other end devices
Due to an 1152A1 PDU’s line-sensing capabilities, this PDU only powers end devices designed to 
receive power from the LAN. When connected to an 1152A1 PDU, such a device (termed Power over 
LAN Enabled) receives both its power and data via the Ethernet cable.
To safeguard devices that are not enabled, an 1152A1 PDU can detect these devices and send them data 
via the Ethernet cable, without transmitting power.
An end device that cannot receive power directly may receive its power and data through an external 
splitter. The splitter separates the power and data before connecting to the end device (see 
AC
Console
1
2
3
4
5
6
13
14
15
16
17
18
19
20
21
22
23
24
7
8
9
10
11
12
1152A1 Power
Distribution Unit
Data &
Power
Data
48Vdc
End Device
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
RJ-45 IN
RJ-45 OUT
Ethernet
Switch/Hub
RJ
-4
5
RJ
-4
5
data
data
data
DC +
data
DC -
data
data
data
data
spare
spare
spare
spare
Da
ta
 In
Da
ta
 &
 P
ow
e
r O
u
t
DC +
DC -
1152A1 Power Distribution Unit