3  Commissioning
MICROMASTER 410    Operating Instructions
6SE6400-5EA00-0BP0
33
3.2 Commission 
Modes
The MICROMASTER 410 is supplied with default parameter settings cover the
following:
Ø  The motor rating data; voltage, current and frequency data is keyed into the
inverter to ensure that the motor is compatible with the inverter. (A standard
Siemens motor is recommended).
Ø  Linear V/f motor speed, controlled by an analogue potentiometer.
Ø  Maximum speed 3000 min
-1
 with 50 Hz (3600 min-1 with 60 Hz); controllable
using a potentiometer via the inverter’s analogue inputs.
Ø  Ramp-up time / Ramp-down time = 10 s.
If more complex application settings are required, please refer to the Parameter
List.
Front Panels for the MICROMASTER 410
For instructions on how to exchange/replace
the Operator Panels, please refer to the
appropriate Appendix A in this manual.
To change the parameters of the inverter you
will require the optional Operator Panel. To
assist in the quick and efficient changing of
parameters, commissioning software tools
such as DriveMonitor can be used; this
software is supplied on the CD-ROM and can
also be downloaded from the Internet.
To allow the parameters to be changed using
the software tools, the PC to Inverter
Connection Kit is required.