DataTrak Operation
313840G
7
DataTrak Operation
NOTE: The display (AE) will turn off after 1 minute to 
save battery life. Press any key to wake up the display.
NOTE: DataTrak is factory set to 685 cc/cycle. This set-
ting is accurate for pumping water at a medium speed 
on a Husky 1050 pump (approximately 20 gpm). The 
DataTrak can be calibrated for use with a different Husky 
model, for greater accuracy, for different pump speeds, 
or for different viscosity fluids. See Calibration Proce-
dure
, page 9.
Setup Mode
1.
See Fig. 1. Press and hold 
 for 5 seconds until 
Setup menu appears.
2.
To enter settings for flow rate units and displace-
ment, press 
 to change the value, then
 to 
save the value and move the cursor to the next data 
field. 
3.
To enter setting for runaway (if equipped), enter 
pump speed in cycles/min. The exact setting will 
vary by pump speed and viscosity of fluid. Choose a 
setting that is just above the fastest speed expected 
during normal operation.
NOTE: Set the value to zero to disable runaway protec-
tion or if your pump is not equipped with a runaway pro-
tection solenoid.
NOTE: A flashing LED indicates an error that must be 
addressed. The Runaway mode will not stop a runaway 
pump while the LED is flashing.
4.
Move the cursor to the last field, then press 
 
once more to exit Setup mode.
Run Mode
Runaway
1.
If pump runaway occurs, the runaway solenoid will 
actuate, stopping the pump. The LED (AD) will flash 
and the display (AE) will indicate a runaway condi-
tion. The display will cycle through four instruction 
screens.
2.
To reset the runaway solenoid, close the master air 
valve. Wait for air to completely bleed off the air 
motor.
3.
Press 
 to clear the diagnostic code and reset the 
runaway solenoid.
4.
Open master air valve to restart pump.