DataTrak Operation 
8
313840G
NOTE: If the DataTrak does not reset, use a screwdriver 
to push the solenoid release button on the side of the air 
valve.
5.
If the solenoid doesn’t actuate:
a.
Close the master air valve to stop the pump. 
The display will show the Service Component 1 
screen.
b.
See Table 1, Diagnostic Codes, on page 10.
NOTE: To disable runaway monitoring, go to setup 
mode and set runaway value to 0 (zero). See Fig. 1.
Prime/Flush
1.
See Fig. 1. To enter Prime/Flush mode, press any 
key to wake up the display, then press 
. The 
Prime/Flush symbol will appear in the display and 
the LED will flash 
.
2.
While in Prime/Flush mode, runaway protection is 
disabled and the batch totalizer (BT) will not count.
3.
To exit Prime/Flush mode, press any key to wake up 
the display, then press 
. The Prime/Flush sym-
bol will disappear from the display and the LED will 
stop flashing.
Counter/Totalizer
To reset the totalizer, press any key to wake up the dis-
play, then press and hold 
 for 3 seconds.
If AC is set to gallons or ounces, BT and GT dis-
play gallons.
If AC is set to liters or cc, BT and GT display 
liters.
If AC is set to cycles, BT and GT display cycles.
NOTE: Press 
 to toggle between flow rate units and 
cycles. A letter under the BT display indicates that both 
BT and GT are displaying gallons (g) or liters (l). No let-
ter means both BT and GT are displaying cycles.
Display
See Fig. 1. The display (AE) will turn off after 1 minute of 
inactivity in Run mode or 3 minutes in Setup mode. 
Press any key to wake up the display.
NOTE: DataTrak will continue to count cycles when dis-
play is off.
NOTE: The display (AE) may turn off if a high-level static 
discharge is applied to the DataTrak. Press any key to 
wake up the display.
Diagnostics
DataTrak can diagnose several problems with the pump. 
When the monitor detects a problem, the LED (AD, Fig. 
1) will flash and a diagnostic code will appear on the dis-
play. See Table 1, page 10.
To acknowledge the diagnosis and return to the normal 
operating screen, press 
 once to wake up the display, 
and once more to clear the diagnostic code screen.
ti14263a