User ManualTable of Contents1 Introduction8How to use an S610S reader10LED Card Response table101.1 Cabling requirements101.2 Typical S610S Access Control network11Using an Ethernet Control Module (ECM)111.3 S610S/S600S PCB layout112 Quick Guide to setting up S610S123 Connecting an S610S Master Reader143.1 Open the S610 reader case143.2 S610S Master Reader 12V Power and Data connections143.3 Extra settings required, made on the reader14Reader Address14Door Mode14Card Type15Read Head15Auxiliary Devices153.4 Addressing an S610S master reader15S610S Reader in Normal Operation16Telnet or HyperTerm serial network controller163.5 S610S Connecting Master Reader Inputs16Test I/O states using reader’s diagnostic mode173.6 Monitoring Inputs for Cable Tampers17Enable 4-state tamper detect183.7 Using an external read head183.8 S610S Lock and spare output relay connections18Connecting a lock18Using a Fail secure lock connected to a reader19Connecting a Sounder to a spare output relay19Invert relay output194 Connecting an S610S to an Exit Reader204.1 S610S Master Reader 12V Power and Data connections20Setting the Master S610S Exit reader configuration20Devices Application - Setting the S610S Exit reader configuration214.2 S610S Master with Slave input connection table215 Connecting an S610S to a DIU225.1 Connecting an S610S to a DIU210225.2 Connecting a powered lock to a DIU23Using a Fail secure lock connected to a DIU23S610S with DIU Input connection table23Set up the S610S with DIU24Devices Application - Setting the S610S Exit reader and DIU configuration24Local Sounder output246 AC2000 Devices Application tasks266.1 Add the S610S reader to the AC2000 system26Add S610S Exit/slave reader26Enable Read head – S610S only266.2 Changing reader Door Mode TIME duration settings266.3 Changing other reader settings276.4 Access control using PIN Only296.5 Card, Cardswipe and PIN or PIN ONLY options306.6 Extended Timezone configuration317 Door Modes337.1 Door mode347.2 Verification 24, Verification 3234Desfire Verification34Encrypted verification – Mifare Finch347.3 Passenger mode34Interlocking Passenger mode (Lobby Mode)357.4 Control Post mode357.5 PIR mode357.6 Passenger-staff exit mode36Air-Bridge with Passenger-Staff exit mode36Second Swipe Action configuration377.7 Trolley mode387.8 Turnstile Mode38Selecting S610S Turnstile Mode38Single S610S reader – Fail Secure/Fail Safe38Controlling power to a turnstile39Wiring a bidirectional turnstile39S610E/S610S Inputs and Outputs39AC2000 – Configuring Turnstile Mode417.9 Equipment Enable mode42Setting Timing controls on equipment42Functionality42Automatic equipment disable feature43Equipment Enable - Time settings43Equipment Enable card usage outcome codes43Connection Diagram for Equipment mode44AC2000 software settings for equipment mode44Equipment Mode; Input configuration44Alarm Configuration457.10 Multiple badge access458 Interlock468.1 Interlock in Door Mode46Configure the reader’s interlock input46Configure the reader’s interlock output46Configuring Interlock Input IP 3, or IPB (if DIU)468.2 Passenger mode interlock – Lobby Mode47Without a Valve Lobby Controller47No access on interlock47With a Valve Lobby Controller479 Other AC2000 software configurations489.1 To Edit or Add an input for AED alarm management48S610E input table – No DIU48S610E with DIU Input table489.2 Disabling an Input using AC2000 software489.3 Input/output Mapping49Mapping an input to an output499.4 Configuring a spare Output Relay49Connecting a Sounder.509.5 Other AC2000 configuration options50Access Levels5010 S610S onboard diagnostic mode5210.1 Using Diagnostic Mode5210.2 S610S menu tree5210.3 Information Menu53Network53Versions53Database53System5310.4 Test Menu54Local Device54Aux Device54Testing Reader Inputs5410.5 Configure Menu5510.6 Setting the correct readhead technology55Prox:55Card Definition (or Card format)55Smarthead5510.7 Adjusting optical Tamper Thresholds5610.8 Disable diagnostic mode pin5610.9 Updating Firmware56AC000 web configuration tool56Other options may include5711 Appendix5811.1 Check List/Commissioning Sheet5811.2 S400 Exit Reader Connections5811.3 CLK Air Bridge5811.4 S610S Specification Sheet59Size: 3.61 MBPages: 62Language: EnglishOpen manual