VIZIO VS-900 Manual De Usuario

Descargar
Página de 16
TOA VS-900 Programmer’s Guide
7
Log Data Output Request
The VS-900 Log Data Output allows you to monitor most station and system activity. Send the string
below to initiate Log Data flow from individual or multiple exchanges simultaneously. Once the data
stream has been initiated, the VS-900MF will continue to send the log data without re-sending the
request.
Field Name
Length
(Bytes)
Value
Description
Direction
DLE
1
10H
Delimiter
ENQ
1
05H
Enquiry
PC to VS-900MF
DLE
1
10H
Delimiter
ACK
1
06H
Acknowledgement
VS-900MF to PC
DLE
1
10H
Delimiter
STX
1
02H
Start Of Text
Log Data
Request
1
4FH
Log Data Output Request command
Exchanges
2
30H 30H
ON/OFF Status
Exchange #01 –
16
16
30H or 31H OFF = 30H     ON = 31H
DLE
1
10H
Delimiter
ETX
1
03H
End Of Text
BCC
1
xxH
Block Check Character
PC to VS-900MF
DLE
1
10H
Delimiter
ACK
1
06H
Acknowledge
VS-900MF to PC
DLE
1
10H
Delimiter
EOT
1
04H
End of Transmission
After the initial Log Data Request, the VS-900MF will send an enquiry (DLE & ENQ, 10H & 05H) to the
PC when log data is available in the queue. The PC should then respond with an acknowledgement (DLE
& ACK, 10H & 06H) so the log data will be sent from the VS-900MF. This process will repeat until there is
no information left in log data queue.
Field Name
Length
(Bytes)
Value
Description
Direction
DLE
1
10H
Delimiter
ENQ
1
05H
Enquiry
VS-900MF to PC
DLE
1
10H
Delimiter
ACK
1
06H
Acknowledge
PC to VS-900MF
DLE
1
10H
Delimiter
STX
1
02H
Start Of Text
Log Data Sent
1
6F
Log data
Exchange #
2
xxH xxH
Exchange #01 – 16
Time (HH:MM:SS)
6
Hours, Minutes, and Seconds
Line #1
6
Varies, Refer to Appendix A
Line #2
6
Varies, Refer to Appendix A
Line #3
6
Varies, Refer to Appendix A
Line #4
6
Varies, Refer to Appendix A
*Status #
2
xxH xxH
Varies, Refer to Appendix A
DLE
1
10H
Delimiter
ETX
1
03H
End Of Text
BCC
1
xxH
Block Check Character
VS-90MF to PC
DLE
1
10H
Delimiter
ACK
1
06H
Acknowledge
PC to VS-900MF
DLE
1
10H
Delimiter
EOT
1
04H
End of Transmission
VS-900MF to PC