VIZIO VS-900 Manual De Usuario

Descargar
Página de 16
TOA VS-900 Programmer’s Guide
8
Examples
1. Remote Dialing
The data sequence below will remote dial Master Station #1 in Exchange #1 to dial Sub-Station #105 and
initiate communication. The “CC” (Clear) is included to terminate any current Master Station functions.
Note: The total Dialing Contents must be 32 bytes.
Field Name
Length
(Bytes)
Value
Description
Direction
DLE
1
10H
Delimiter
ENQ
1
05H
Enquiry
PC to VS-900MF
DLE
1
10H
Delimiter
ACK
1
06H
Acknowledge
VS-900MF to PC
DLE
1
10H
Delimiter
STX
1
02H
Start Of Text
Remote Dial
1
4EH
Remote Dialing
Command
Exchange #
2
30H 31H
EXCHANGE # "01"
Master Station #
1
31H
MASTER # "1"
Dialing Contents 32 Bytes
43H 43H 31H 30H 35H
20H 20H 20H 20H 20H 20H
20H 20H 20H 20H 20H 20H
20H 20H 20H 20H 20H 20H
20H 20H 20H 20H 20H 20H
20H 20H 20H
"CC105"
DLE
1
10H
Delimiter
ETX
1
03H
End Of Text
BCC
1
79H
Block Check Character
PC to VS-900MF
DLE
1
10H
Delimiter
ACK
1
06H
Acknowledge
VS-900MF to PC
DLE
1
10H
Delimiter
EOT
1
04H
End of Transmission
PC to VS-900MF