Xantrex Technology RC/GS RC7 Manual De Usuario

Descargar
Página de 68
Operation
38
975-0210-01-01
Over Temperature
The “Otemp/Less Load” System Status message indicates the 
inverter/charger transformer and power components have 
exceeded a safe operating temperature. Reduce the load on 
the inverter. When the unit cools, it automatically resets and 
resumes operation. If this condition occurs often, make sure 
the inverter is in a cool location, has adequate ventilation, and 
the cooling fan is operational.
Overload
The “Overload” System Status message appears when the load 
on the inverter/charger exceeds the maximum power rating of 
the unit. Reduce the load and restart the inverter/charger by 
pressing the On/Off button on the RC/GS and RC7 twice.
Figure 4-13 Over-temperature Error Message
Note:
Press any arrow button to cancel the buzzer.
Figure 4-14 Overload Error Message
Inverter
Charge
Batt. Full
Error
822-4A-001
System Status:
Otemp/Less Load
!
Error LED 
ON
Buzzer sounds
Error Condition
Remedy
Inverter
Charge
Batt. Full
Error
822-4A-001
System Status:
Overload
!
Error LED 
ON
Buzzer sounds (press 
arrow button to cancel)
Error Condition
RC-GS_manual.book  Page 38  Thursday, May 26, 2005  4:58 PM