Xantrex Technology RC/GS RC7 Manual De Usuario

Descargar
Página de 68
Operation
40
975-0210-01-01
Charger Fault
The “Charger Fault” System Status message appears when an 
internal error is detected in the inverter/charger during 
charging. In addition, the red Error LED is on and the buzzer 
sounds. After 15 minutes, the charge relay disconnects and 
the inverter section shuts down. The screen shows “System 
Status: Overload.”
This fault indicates a hardware failure in the charger circuitry 
of the inverter/charger. If this message appears, contact 
Xantrex or the nearest Service Center.
Figure 4-17 Charger Fault Error Message
Inverter
Charge
Batt. Full
Error
822-4A-001
System Status:
Charger Fault
!
Error LED 
ON
Buzzer sounds 
(press arrow 
button to cancel)
Error Condition
RC-GS_manual.book  Page 40  Thursday, May 26, 2005  4:58 PM