LOCATION 1 
DESTINATION SELECTION FOR REPORT CONTROL 1 (1 segment) 
The NX-7002 contains up to six report controls. Each report control can be defined for SMS 
reporting, TCP/IP reporting or email reporting (not yet available). This location contains the 
report destination for report control 1. Select from the table below. 
DATA 
FORMAT 
DESCRIPTION 
Disabled 
Report control 1 is disabled 
TCP/IP 1 
Reporting to TCP/IP receiver 1 
TCP/IP 2 
Reporting to TCP/IP receiver 2 
Email 1 
Email Reporting to Email Account 1 (not yet 
available) 
Email 2 
Email Reporting to Email Account 2 (not yet 
available) 
SMS 1 
SMS Reporting to Mobile Phone 1 
SMS 2 
SMS Reporting to Mobile Phone 2 
 
LOCATION 2   
BACKUP DESTINATION SELECTION FOR REPORT CONTROL 1 (1 segment) 
If the primary destination selection (location 1) fails, a backup destination can be selected. If 
using another device as the backup destination, for example, panel dialler, set the reporting 
format (SIA or CID) in location 0, segment 2, option 1 and enable test report events for the 
backup device. This location contains the backup report destination for report control 1. Select 
from the table below. 
DATA 
FORMAT 
DESCRIPTION 
Disabled 
Backup Report control 1 is disabled 
TCP/IP 1 
Backup Reporting to TCP/IP receiver 1 
TCP/IP 2 
Backup Reporting to TCP/IP receiver 2 
Email 1 
Backup Email Reporting to Email Account 1 (not yet 
available) 
Email 2 
Backup Email Reporting to Email Account 2 (not yet 
available) 
SMS 1 
Backup SMS Reporting to Mobile Phone 1 
SMS 2 
Backup SMS Reporting to Mobile Phone 2 
255 
Other dialler 
The NX-7002 is not used as backup. Instead another 
dialler is used (for example: panel dialler) 
 
LOCATION 3 
REPORT DELAY FOR REPORT CONTROL 1 (1 segment) 
The delay in seconds before the NX-7002 GPRS module reports. If any other events occur 
during this delay, they are sent with the first event in one message if using SMS reporting. This 
does not apply if using TCP/IP reporting (it does not support multiple events in one message). 
This can be from 0 to 255 seconds. 
NX-7002 Installation manual 
Page 14 
 