10.2.2 Communication Setting
- Baud Rate Select:
9600bps (fixed)
- Data bits:
8 bits (fixed)
- Parity:
None (fixed) 
- Stop Bits:
1 (fixed) 
10.2.3 Command Message Reference
PC sends to Monitor command packet followed by “CR”. Every time PC sends 
control command to the Monitor, the Monitor shall respond as follows:
1.  If the message is received correctly it will send “+” (02Bh) followed by “CR” 
(00Dh)
2.  If the message is received incorrectly it will send  “-” (02Dh) followed by “CR” 
(00Dh)
10.3 Protocol
10.3.1 Set-Function Listing
The PC can control the TV/DS for specific actions. The Set-Function command 
allows you to control the TV/DS behavior in a remote site through the RS232 port.  
The Set-Function packet format consists of 9 bytes.
Set-Function description: 
Length: 
Total Byte of Message excluding “CR”.
TV/DS ID
Identification for each of TV/DS (01~98; default is 01)
If we want to set all TV/DS settings, use the TV/DS ID “
99”, and 
it will not have 
Reply command on this function.
The TV/DS ID can be set via the OSD menu for each TV/DS 
set.
Command Type Identify command type, 
“s” (0x73h) : Set Command
“+” (0x2Bh) : Valid command Reply
“-“ (0x2Dh) : Invalid command Reply
Command: 
Function command code: One byte ASCII code.
Value[1~3]: 
Three bytes ASCII that defines the value.
CR
0x0D