Viewsonic CDE5501 Manual De Usuario

Descargar
Página de 85
62
Set-Function format 
Send: (Command Type=”s”)
Name  Length
ID
Command 
Type
Command Value1 Value2 Value3  CR
Byte 
Count 
1 Byte  2 Byte
1 Byte
1 Byte 
1 Byte  1 Byte  1 Byte  1 Byte 
Bytes 
order
1
2~3
4
5
6
7
8
9
NOTE:  
For VT2405LED-1 and VT3205LED, the set “Power on” command is the exception.
Reply: (Command Type=”+” or “-”)
Name 
Length
ID
Command 
Type
CR 
Byte 
Count 
1 Byte  2 Byte
1 Byte
1 Byte 
Bytes 
order
1
2~3
4
5
NOTE: 
1.  
The reply for “Power on” command is the exception for VT2405LED-1 and 
VT3205LED. It’s 0x322B0D ( 2+<CR>).
2.  When PC applies command to all displays (ID=99), only the #1 set needs to reply 
by the name of ID=1. 
Example1: Set Brightness as 76 for TV-02 and this command is valid
Send (Hex Format) 
Name  Length
ID
Command 
Type
Command Value1 Value2 Value3  CR
Hex 
0x38
0x30 
0x32
0x73
0x24
0x30
0x37
0x36 0x0D
Reply (Hex Format)
Name 
Length
ID
Command 
Type
CR 
Hex
0x34
0x30 
0x32
0x2B
0x0D
Example2: Set Brightness as 176 for TV-02 and this command is NOT valid
Send (Hex Format) 
Name  Length
ID
Command 
Type
Command Value1 Value2 Value3  CR
Hex
0x38
0x30 
0x32
0x73
0x24
0x31
0x37
0x36 0x0D