A diaphragm-type expansion tank suitable for potable 
water will normally eliminate this weeping condition. 
Please read and follow the manufacturer’s instructions for 
the installation of such tanks.
MASSACHUSETTS CODE
DOES NOT ALLOW THIS
TYPE OF INSTALLATION.
Must Be Vertical To 
Remove Air Bubbles 
Domestic
Hot Water
Out
Mixing
Valve
Hot
Water
Out
Unions
To Air
Handler
Vacuum
Relief
Valve
Expansion Tank
Cold Water Inlet
Flow Control
Pump
Valve
In
Out
Coil
Air
Handler
Shut-Off
Valve
Typical Mixing Valve Installation Combination
Space Heating/Potable Water Heating System
FIGURE 16
Electrical Connections                                                        
Before plugging in the water heater, always make sure:
• 
The Voltage and frequency correspond to that specified  
 
on the water heater.
• 
The electrical outlet has the proper overload fuse or    
 breaker 
protection.
• 
Unit is to connect to a 120VAC electrical supply outlet      
      (extension cord is not allowed).
IMPORTANT: Do not use an extension cord to connect the 
water heater to an electrical outlet.
• 
The water heater and the outlet are properly grounded.
• 
Installed in accordance with prevailing provisions of    
 
local codes, or in the absence of such, National Electric  
 
Code, ANSI/NFPS 70 current edition.
Completely fill the tank with water and check all con- 
nections for leaks. Open the nearest hot water faucet and 
let it run for three (3) minutes to purge the water lines of 
air and sediment and to ensure complete filling of the tank. 
The Electrical power may then be turned on. Verify proper 
operation after servicing.
WARNING
Electric Shock Hazard
Disconnect power before 
servicing.
Replace all parts and panels 
before operating.
Failure to do so can result in
death or electrical shock.
 
Pressure 
Switch
Control Display
Power Supply
Transformer
Igniter/Flame
Sense Connector
Air Intake
Chamber Fan
Anode
Rod
Gas Control 
Valve / Thermostat
CAUTION:
LABEL ALL WIRES PRIOR TO 
DISCONNECTION WHEN SERVICING 
CONTROLS. WIRING ERRORS CAN CAUSE 
IMPROPER AND DANGEROUS OPERATION. 
VERIFY PROPER OPERATION AFTER SERVICING.
FV
Sensor
CAUTION:
 
DO NOT USE AN EXTENSION 
CORD TO CONNECT THE 
TRANSFORMER TO AN 
ELECTRICAL OUTLET.
Also see Water System Piping for additional instructions on 
the safe and correct installation and operation of this water 
heater. 
Solar Installation                                                         
If this water heater is used as a solar storage heater 
or as a backup for the solar system, the water supply 
temperatures to the water heater tank may be in excess of 
120°F. A mixing valve or other temperature limiting valve 
must be installed in the water supply line to limit the supply 
temperature to 120°F.
NOTE: Solar water heating systems can often supply 
water with temperatures exceeding 180°F and may result 
in water heater malfunction.
Wiring Diagram