Adding/Replacing Sensors
22
To Add or Replace a Sensor using the Programming Buttons under 
the Panel Cover
Note  
The sensor number can be 
changed during program 
mode by pressing the num-
bered keys after pressing 
the sensor button. Sensors 
can be numbered 01 to 24. 
Be sure to enter 0 before the 
number for sensor numbers 
1 to 9. The sensor number 
cannot be changed after it 
has been programmed.
1. Open the front cover.
2. Enter the Utility 1 or Utility 2 Access Code.
3. Press the Add button from the Start menu. The panel announces “Select from Main Menu.”
4. Press Sensor from the Main Menu. 
The panel will announce “Press button on sensor X.” X is the next available sensor number. If 
24 sensors are already programmed into the panel the panel says “Invalid. Twenty-four sen-
sors already programmed.”
5. Trip the sensor. 
See Table 8 for descriptions of how to trip each type of sensor. The panel will announce 
“Press status to accept sensor.” DO NOT press Status at this time. Move on to Step 6.
6. If necessary, change the Sensor name by pressing the Option # button.
7. Press the Done button to program the sensor. 
The system will announce the sensor name, type and number.
Table 8: Programming Sensors
Sensor Type
To Trip
Sensor Type Options
Personal Help Button
Press the help button on the sensor.
Emergency Sensor Type Not Supervised
Emergency Sensor type Supervised
Pendant Help Button
Press the help button on the sensor.
Emergency Sensor Type Not Supervised
Emergency Sensor type Supervised
Door/Window Sensor
With the Door/Window Sensor cover 
removed, press the Program button on 
the top of the sensor.
Activity Sensor type Supervised
Activity Sensor type Not Supervised
Freeze Sensor
With the Freeze Sensor cover 
removed, press the Program button on 
the top of the sensor.
Freeze Sensor type Supervised
Water Sensor
With the Water Sensor cover 
removed, press the Program button on 
the top of the sensor.
Water Sensor type Supervised
Smoke Alarm
Remove the base of the Smoke Alarm
Smoke Sensor type Supervised
Carbon Monoxide (CO) 
Alarm
Plug in the CO Alarm. Within 60 sec-
onds of plugging in, press and hold the 
Test/Reset button until you hear 6 
beeps.
Carbon Monoxide Sensor type Supervised
Motion Sensor
Remove the sensor from its mounting 
plate.
Activity Sensor type Supervised
Activity Sensor type Not Supervised
Repeater
With the Repeater cover removed, 
press the tamper switch spring on the 
circuit board.
Repeater module type Supervised