Galil DMC-3425 Manual De Usuario

Descargar
Página de 210
DMC-3425 
Chapter 2  Getting Started
  9 
Step 1.  Determine Overall Motor Configuration 
Before setting up the motion control system, the user must determine the desired motor configuration.  
The DMC-3425 can control standard brush or brushless servo motors, sinusoidally commutated 
brushless motors or stepper motors.  For control of other types of actuators, such as hydraulics, please 
contact Galil. The following configuration information is necessary to determine the proper motor 
configuration: 
Standard Servo Motor Operation: 
The DMC-3425 has been setup by the factory for standard servo motor operation providing an analog 
command signal of +/- 10 volt.  The position of the jumpers at JP2/JP3 determines the type of output 
the controllers will provide, analog motor command or PWM output. The installation of these jumpers 
is discussed in the section “Configuring Jumpers on the DMC-3425”.  Figure 2.2 shows how the 
jumpers are configured for the standard output mode. 
The DMC-3425 controller will output the analog command signal to either brush or brushless servo 
amplifiers.  Please note that if the brushless amplifier provides the sinusoidal commutation, the 
standard servo motor operation from the controller will be used.  If the commutation is to be performed 
by the controller, please see below.  
Sinusoidal Commutation: 
Please consult the factory before operating with sinusoidal commutation. 
Sinusoidal commutation is configured through a single software command, BA.  This setting causes 
the controller to reconfigure the control axis to output two commutated phases.  The DMC-3425 
requires two DAC outputs for a single axis of commutation.  Issuing the BA command will enable the 
second DAC for commutation.   
If a DMC-3425 is used for sinusoidal commutation, the second axis will be used for the second DAC 
phase.  Please note that if the DMC-3425 is used for sinusoidal commutation, it will still be 
represented by two axes within the distributed system, even though only one axis is truly active.  The 
DMC-3415 in brushless mode will take only a single axis within the distributed system.   
Further instruction for sinusoidal commutation connections are discussed in Step 6. 
Stepper Motor Operation: 
The DMC-3415 can be configured to operate in stepper mode by installing a hardware jumper and 
issuing a software command.  The DMC-3425 can be configured to operate with two stepper motors by 
ordering the DMC-3425-Stepper option from the factory.  To configure the DMC-3425 for stepper 
motor operation, the controller requires a jumper for the stepper motors and the command, MT, must 
be given.  The installation of the stepper motor jumper is discussed in the following section entitled 
"Configuring Jumpers on the DMC-3425".   Further instructions for stepper motor connections are 
discussed in Step 8b. 
Step 2. Configuring Jumpers on the DMC-3425 
Master Reset and Upgrade Jumper 
JP1 contains two jumpers, MRST and UPGD.  The MRST jumper is the Master Reset jumper.  When 
MRST is connected, the controller will perform a master reset upon PC power up or upon the reset 
input going low.  Whenever the controller has a master reset, all programs, arrays, variables, and 
motion control parameters stored in EEPROM will be ERASED. 
The UPGD jumper enables the user to unconditionally update the controller’s firmware.  This jumper 
is not necessary for firmware updates when the controller is operating normally, but may be necessary 
in cases of corrupted EEPROM.  EEPROM corruption should never occur, however, it is possible if