DMC-3425 
Chapter 4 Communication
  45 
 
CAUTION:  Be sure that there is only one BOOT-P server running.  If your network has DHCP or BOOT-P 
running, it may automatically assign an IP address to the controller upon linking it to the network.  In order to 
ensure that the IP address is correct, please contact your system administrator before connecting the controller 
to the Ethernet network. 
 
The second method for setting an IP address is to send the IA command through the DMC-3425 main 
RS-232 port.  The IP address you want to assign may be entered as a 4 byte number delimited by 
commas (industry standard uses periods) or a signed 32 bit number. (Ex.  IA 124,51,29,31 or IA 
2083724575) Type in BN to save the IP address to the controller's non-volatile memory. 
NOTE:  Galil strongly recommends that the IP address selected is not one that can be accessed across 
the Gateway.  The Gateway is an application that controls communication between an internal network 
and the outside world. 
The third level of Ethernet addressing is the UDP or TCP port number.  The Galil controller does not 
require a specific port number.  The port number is established by the client or master each time it 
connects to the controller.
 
Ethernet Handles 
An Ethernet handle is a communication resource within a device.  The DMC-3425 can have a 
maximum of 8 Ethernet handles open at any time.  When using TCP/IP, each connection to a device, 
such as the host computer, requires an individual Ethernet handle.  In UDP/IP, one handle may be used 
for all the masters, but each slave uses one.  (Pings and ARP's do not occupy handles.)  If all 8 handles 
are in use and a 9
th
 master tries to connect, it will be sent a "reset packet" that generates the appropriate 
error in its windows application. 
The TH command may be used to indicate which handles are currently connected to and which are 
currently free. 
Global vs. Local Operation 
Each DMC-3425 controls two axes of motion, referred to as A and B.  The host computer can 
communicate directly with any DMC-3425 using an Ethernet or RS-232 connection.   When the host 
computer is directly communicating with any DMC-3425, all commands refer to the first two axes as 
A and B.  Direct communication with the DMC-3425 is known as LOCAL OPERATION. 
The concept of Local and Global Operation also applies to application programming.  See Chapter 7:  
Global vs. Local Programming.