Avaya 03-300430 Manual De Usuario
Communication Manager Maintenance-Object Repair Procedures
764 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
2000
ABRT
Response to the test request was not received within the allowable time
period.
period.
1. Retry the command at 1-minute intervals up to 5 times.
2.
S8700 | 8710
: If the test continues to abort with error code 2000, check
for power problems with the PN’s A carrier.
S8700 MC
: Look for and resolve every AC-POWER and CARR-POW
alarm in a multicarrier cabinet or DC-POWER alarm in a single-carrier
cabinet.
cabinet.
S8700 IP
:Look for and resolve every RMC-ENV alarm. Repeat the test.
3.
S8700 MC
: If the test continues to abort with error code 2000, check for
and resolve every MAINT error in a PN. Repeat the test.
2029
S8700 |
8710
S8500
:23
19,
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
Table 264: Test #122 Cabinet Temperature Query Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 7