Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
764 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2.
S8700 | 8710
: If the test continues to abort with error code 2000, check 
for power problems with the PN’s A carrier. 
S8700 MC
: Look for and resolve every AC-POWER and CARR-POW 
alarm in a multicarrier cabinet or DC-POWER alarm in a single-carrier 
cabinet. 
S8700 IP
:Look for and resolve every RMC-ENV alarm. Repeat the test.
3.
S8700 MC
: If the test continues to abort with error code 2000, check for 
and resolve every MAINT error in a PN.  Repeat the test.
2029 
S8700 | 
8710
 
S8500
:23
19, 
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
Table 264: Test #122 Cabinet Temperature Query Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 7