Goodman Mfg GSH13 Manual De Usuario
6
www.goodmanmfg.com
SS-GSH13
P
roduct
S
PecificationS
W
iRinG
D
iaGRam
Wiring
is
subject
to
chang
e.
Alw
ay
s
re
fer
to the wiring diagr
am or the
unit
for the mos
t up-t
o-da
te
wiring.
⚠
W
arning
High V
oltage:
Disc
onnect
all
po
w
er
be
for
e
ser
vicing
or
ins
talling
this
unit.
Multiple
po
w
er
sour
ces
ma
y
be
pr
esen
t.
Failur
e
to
do
so
ma
y
cause
pr
operty
damag
e,
per
sonal
injur
y,
or
dea
th.
⚡
BK
BK
DF1
DF2
H V D R
RD
D
FT
WH
W2
LVD
R
RD
R
R
R
RD
BK
YL
BL
O
O
O
Y
C
C
OR
DC
W2
WH
RD
RD
BK
R
V
C
D
FT
R
DC
Y
C
D
FT
C
R
IN
DOOR P
OWER
SU
PPLY
W2
R
V
C
C
Y
O
O
R
O
LVD
R
W2
(IF
USED)
NOT
E
3
CH
H
V
DR
DF2
DF1
LPS
YL
YL
D
FT
BK
CO
MP
MAI
N
A
UX
BK
RD
S
R
C
YL
PU
BR
BK
MAI
N
AU
X
CM
IO
BL
YL
BK
1
2
5
SR
RCCF
RD
BL
YL
YL
BL
BK
RD
RD
BK
BK
BK
C
T1
L1
T2
L2
BL
RD
SC
CONTR
OL
B
OX
LVJB
WI
R
IN
G CO
D
E
FAC
TORY WIRI
N
G
HI
G
H V
OL
TA
GE
LOW V
OL
TA
GE
OPT
IO
N
AL
HI
G
H V
OL
TA
GE
FIELD WIRING HI
G
H V
OL
TA
GE
O
U
TDOOR P
OWER S
U
PPLY
SEE R
AT
IN
G PL
AT
E
C
OM
PO
N
ENT
C
O
D
E
C --------
------- CON
TA
C
TOR
C
H ------------- CRA
N
KC
ASE
H
EA
TER
C
H
S --------
----- CRA
N
KC
ASE
H
EA
TER SWI
TC
H
CM -----------
- O
U
TDOOR F
AN
MO
TOR
COMP -------- COMPRES
SOR
DC --------
----- DEFROST C
O
N
TROL
DFT ----------- DEFROS
T
TH
ERMOS
TA
T
H
VDR --------
HI
G
H
VOL
TA
GE DEFROS
T RELAY
IO ---------
----- IN
TER
N
AL
O
VERLO
AD
LPS -------
----- LOW PRESSUR
E SWI
TC
H
LVD
R --------
- LOW V
OL
TA
GE DEFROS
T RELAY
LVJB ----------
LOW V
OL
TA
GE JU
N
C
TIO
N
BOX
RCCF -------
-- RU
N
C
APAC
IT
O
R
FOR CO
MPRESS
OR & F
AN
R
VC --------
--- REVER
SI
N
G
VAL
VE COIL
SA ------------- ST
AR
T A
SSIS
T
SC --------
----- ST
AR
T C
APAC
IT
O
R
FOR CO
MPRESS
OR (OP
TIO
N
AL)
SR --------
----- ST
AR
T RELAY FOR C
OMPRE
SSOR (OP
TIO
N
AL)
CO
N
TROLS S
H
OWN WI
TH
TH
ERMOS
TA
T IN '
OFF' POSI
TIO
N.
C
OLO
R
C
O
D
E
BK ---------
------ BLACK
BL ------
--------
- BLUE
BR --------
------- BROWN
OR -----------
---- ORA
N
GE
PU --------------- PURPLE RD --------
------- RED
W
H -------------- WHI
TE
YL ---
--------
---- YEL
LOW
NOT
E
1
R
C
Y
O
RD
BL
YL
OR
LPS
CM
AU
X
MA
IN
F
C
HC
(IF
USED)
L2
L1
C
T2
SC
RCCF
1
2
SA
SR
S
5
AU
X
R
MA
IN
C
T1
ALTER
NAT
E D
OU
BLE
PO
LE
CON
TAC
TO
R O
NLY
CO
MP
N
O
TES:
1. TO I
N
DOOR
U
NI
T LOW
VOL
TA
GE
TERMI
N
AL BL
OCK & I
N
DOOR
TH
ERMOS
TA
T.
2. ST
AR
T A
SSIST
FAC
TORY EQ
UI
PPED W
H
E
N
REQ
UI
RED.
3. CRA
N
KC
A
SE
H
EA
TER & CR
AN
KC
A
SE
H
EA
TER SWI
TC
H
ARE
FAC
TORY I
N
ST
ALLED
OPT
IO
N.
4. USE C
OPPER C
O
N
D
U
C
TOR O
NLY.
U
SE
N.
E.C. CLASS 2 WIRE
RD
SA
(IF
USED)
NOT
E
2
T1
L1
T2
L2
0140R0
0019P-B
EQ
U
IP
M
EN
T G
RO
U
N
D
SEE N
O
TE
4
A
LTE
R
N
ATE
DO
U
BLE P
O
LE
CO
N
TAC
TO
R
H
F
C
YL
RD
PU
BR
YL
YL
RD
PU
IO
IO
BK
C
HS
GR
RD
BK
RD
CH
(IF
USED)
SEE
N
O
TE 3
BK
RD
BK
C
HS