4. Default Setting: 
 
Master code 1234 
Relay time  5 
Pressed key delay 30 seconds 
Setting mode delay time 50 seconds 
 
5. Operation Instruction: 
 
‹
  Enter Program Mode:  
1.  Compose twice the master code (Factory master is 「1234」)  
→ 2 beeps → you are now in the "programming mode". 
2.  After 50 seconds if you have not entered any codes or data, the system will 
automatically exit from the programming mode.  
3.  After 30 wrong codes attempts at the master code the lockout facility will operate. 
 
‹
  Exiting from the program mode: 
1. Press「#」 to exit from the programming mode. 
2.  After 50 seconds if you have not entered any codes or data, the system will 
automatically exit from the programming mode.  
3.  After 30 wrong codes attempts at the master code the lockout facility will operate. 
 
‹
  Add PIN codes  
Enter the Programming mode, Enter the slot position code 「*001~*099」→????? 
Input 4 digit PIN codes→ (beep) enrolled Æ(repeat) 
Press 「#」 to exit from the programming mode, or program other operating. 
Note 1:
 The codes「0000」,「1234」or master code are not be used for PIN code. 
Note 2:
 Random user codes operate open door:「?????????????????????????*
***」
,「???….」random codes,「****」4 digit  user codes. (Random codes 
and correct user codes total 29 digits.) 
 
‹
  To Delete a User Code: 
         
Enter the Programming mode→ Press the slot position code of your choice to delete 
(example "06") →Press「*006」→「0000」→(beep)→delete→Press「#」 to exit 
from the programming mode, or programming other operating.
  
       
 
 
‹
  To Program Relocking Timer 
        
Enter the Programming mode, 
A. Relay:Press「*100」Followed by the number of seconds the relay should 
open→「05」=5 seconds(01 ~99 = seconds)→(beep)→enrolled → Press 
#」 to exit from the programming mode, or program other operating. 
B. Enter「00」Sets the relay to latching mode.
 
(Correct code entered opens the relay, 
and the relay stays open until the correct code is entered again). 
 
‹
  Changing the Master codes: 
        
Enter the Programming mode, Enter「*000」Followed by the new 4 digit master 
code→(beep)→enrolled→Enter 「#」 to exit from the programming mode, or 
program other operating. 
 
‹
  Master Code reset to Factory 「1234」 
Insert the jumper RESETÆ 1-2 positionÆ5 audible beepsÆReset successfulÆ Return 
Insert the jumper to 2-3 positions.