Empire Comfort Systems DV-55E-5 Manual De Usuario

Descargar
Página de 20
19563-1-0706
Page 13
The appliance, when installed, must be electrically grounded in accordance 
with  local  codes  or,  in  the  absence  of  local  codes,  with  the  National 
Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, 
if an external electrical source is utilized.  This appliance is equipped 
with a three-prong [grounding] plug for your protection against shock 
hazard  and  should  be  plugged  directly  into  a  properly  grounded 
three-prong receptacle.  Do not cut or remove the grounding prong 
from this plug.  For an ungrounded receptacle, an adapter, which has 
two prongs and a wire for grounding, can be purchased, plugged into the 
ungrounded receptacle and its wire connected to the receptacle mounting 
screw.  With this wire completing the ground, the appliance cord plug can 
be plugged into the adapter and be electrically grounded.  
CAUTION:  Label all wires prior to disconnection when servicing 
controls.  Wiring errors can cause improper and dangerous operation.  
Verify proper operation after servicing.  
Note:  For testing flame sensor circuit use a micro-amp meter in series 
with sensor.  Minimum current should be 1 micro-amp during operation.  
Be careful as flame sensor is in the 115VAC circuit.  If current is below 1 
micro-amp, remove sensor, clean with light sandpaper and retest. 
Note: This heater is equipped with a remote bulb electronic thermistor 
control located down low at the back of the furnace. Sometimes due to 
field locations different air currents may effect the control sensing of the 
thermistor. This sensing bulb can be re-located if necessary to provided 
for better room air sensing and control. 
Replacement of Thermistor with 24 Volt Wall Thermostat
  1.  If furnace is installed, turn off gas supply and electric supply.
  2.  Remove casing front.
  3.  Remove black hose from front nipple on pressure switch.
  4.  Remove junction box cover (4 screws).
  5.  Please  refer  to  wiring  diagram  for  removal  of  the  following 
wires.
  6.  Internal Electronic Thermostat/Temperature Control Board
Attention!  No 24 volt wall thermostat wires are to be attached 
to the internal electronic thermostat.
  7.  Control Board
A.  Remove white wire form screw marked W.
B.  Remove yellow wire from screw marked C.
C.  Remove red wire from screw marked R.
  8.  Route (2) wires from any 24 volt wall thermostat through the 
casing back of furnace to the screws marked W and R on the 
control board.
  9.  Replace junction box cover (4 screws).
  10.  Replace black hose onto front nipple on pressure switch.
  11.  Replacement  of  thermistor  with  24  volt  wall  thermostat  is 
completed.
CIRCULATING AIR BLOWER
WHT
FS
LS
RED
YEL
RED
BLK
1
PUR
PUR
INDUCER
BLOWER
BLU
BLU
6
5
3
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED
WITH A WIRE OF AT LEAST 105
° C TEMPERATURE RATING.
LIMIT SWITCH
SECONDARY
FIELD INSTALLED
THERMOSTAT
24 VOLT
115 VAC
SWITCH
LIMIT
3A FUSE
GND
BLACK
WHITE
ON/OFF
ROLLOUT
PRESSURE
SWITCH
R-8191
VALVE
GAS
TRANSFORMER
24 VAC
PRIMARY
115 VAC
COMMON
DISCONNECT INTEGRAL THERMOSTAT "R", "W", AND "C" LEADS AND ATTACH WALL THERMOSTAT AS SHOWN
R
W
5
6
PS
ROS
RED
GRN
ORG
7
8
9
ORG
ELECTRONIC
THERMOSTAT
INTEGRAL
WHT
YEL
RED
2
3
GR
Y
BRN
BRN
GV
GR
Y
24
V
WH
T
BLK
11
5
V
OPTIONAL WALL MOUNT THERMOSTAT
XFMR
ON/OFF
BLACK NEUTRAL
RIBBED
INSULATION
BLACK HOT
SMOOTH
INSULATION
CIRCULATING AIR
BLOWER MOTOR
RED LED
STATUS
LIGHT
IGN
HOT SURFACE
IGNITOR
POWER SWITCH
INDUCER MOTOR
FLAME SENSOR
COMBUSTION AIR