INSTALLATION OF THE SUPER 
STATION 
OR A STANDARD WALL PUSH 
BUTTON  
 
The Super Station (Deluxe Wall Pushbutton Station) is 
a 7 function station designed to work with and 
maximize the operation of your  opener.  Connection 
to any other operator may damage the operator and/or 
the Super Station.  Only connet one Super Station to 
the operator.  Do not connect more than one Super 
Station to the Operator. 
If desired, a standard wall push button may be 
installed and connected to your opener as an alternate 
to the Super Station or in addition to the Super Station.  
A standard wall push button is not included in your 
hardware package, it can be purchased from your 
professional installing dealer or a door bell button 
[without light] can be substituted. The operating 
parameters for the standard wall push button are 
outlined on a page that  follows to see if that mode of 
operation is right for you. The Super Station is 
included with your opener and it’s installation is 
recommended, the Super Station will provide full 
control over the garage door at all times. 
 
YOU MAY CONNECT ONLY ONE SUPER 
STATION PER OPERATOR - 
ADDITIONAL STANDARD WALL PUSH 
BUTTONS MAY BE CONNECTED TO THE 
OPERATOR 
STEP 1:  
After determining a suitable location, 
usually near the access door and at least 5 feet above 
the floor to prevent use by children, use the Super 
Station or the standard wall push button as a guide to 
mark the mounting holes.  Drill holes for drywall 
anchors or screws.  NOTE: Do not mount directly to 
masonry walls.  Use backer board.
 
of 2-conductor, #22 gauge wire (or heavier) is 
required to connect either control to the garage door 
operator.  Strip approximately 2” of the wire jacket 
from one end and 1/2” of insulation from each wire.  
Carefully connect one wire to each of the two 
terminals. Carefully tuck the loose wires into the case 
and mount the unit using appropriate screws.
 
 
STEP 3:  
Run the wire from the control to the 
operator, supporting it at 18” intervals with suitable 
staples.  Leave a sufficient length to make the 
necessary connections to the operator terminal strip. 
WARNING:  SOME LOCAL BUILDING CODES 
DO NOT ALLOW SURFACE WIRING.  BE 
SAFE AND CHECK WITH YOUR LOCAL 
BUILDING INSPECTOR FIRST. 
 
STEP 4:  
Ensure power is OFF to the opener or 
disconnect the power from the opener.  Strip 
approximately 4” of jacket from the end of the wire 
and 1/2” insulation from each wire.  
Connect to terminals 0 and 1 as shown in 
the illustration at left. Support the wire near 
the 
operator 
with wire 
ties.
 
See Step 5, 
next page. 
 
 
WARNING 
A CHILD OPERATING THE DOOR 
CONTROLS RISKS INJURY — OR 
DEATH — TO HIMSELF AND OTHERS. 
DO NOT ALLOW CHILDREN TO 
OPERATE ANY DOOR CONTROLS.   
MOUNT THE PUSHBUTTON AT LEAST 
5 FT FROM THE FLOOR, OUT OF 
REACH OF CHILDREN. 
CONTROL AND AUXILIARY EQUIPMENT 
WARNING 
IMPROPER DOOR OPERATION 
COULD CAUSE INJURY OR DEATH.  
WARNING LABEL MUST BE 
MOUNTED ON WALL NEAR  THE 
PUSHBUTTON.  ALL WARNINGS AND 
INSTRUCTIONS ON THE LABEL 
SHOULD BE STRICTLY ADHERED TO. 
!
Child can be pinned under automatic garage 
door. Death or serious injury can result.
•  Never let child walk or run under moving door.
•  Never let child use door opener controls.
•  Always keep moving door in sight.
•  If person is pinned, push control button or use 
emergency release.
•  Test door opener monthly:
Refer to your owner’s manual
Place one-inch object (or 2x4 laid flat) on floor.
If door fails to reverse on contact, adjust opener.
If opener still fails to reverse door, repair or replace opener.
W AR N I N G  
104350 
CONTROL BUTTON 
WARNING LABEL 
PUSHBUTTON
4
3
2
1
0
TWO WIRE
OPERATOR
RECEIVER
TRANSMITTER
(DELUXE PUSHBUTTON)
SUPER STATION
T2
T1
PHOTOCELL SERIES CONNECTION (RECEIVER FIRST)
SAFE FINISH PHOTOSYSTEM
CONNECTIONS
WIRE NUT