Maintenance and Adjustments
6
   
CAUTION
Door closing force is FACTORY set and requires no adjustment 
for normal operation.
NEVER adjust the force settings to compensate for damage,  
  including an unbalanced door, binding door track, or broken  
 spring.
• Perform monthly a CONTACT REVERSE TEST. See page 8.
ADjUSTMENT GUIDES
Force Settings
Force settings are pre programmed at the factory and “learned”  
during the Open/Close Limit settings steps (see pages 6-7). For normal 
use, these settings should not need adjustment with this unit.
However, conditions possibly requiring adjustment are:
1. Doors with very stiff weather seals.
2. Doors that start down, STOP, and reverse before closing.
3. Doors that start up, but STOP before they completely open.
Force Adjustment
(continued next page)
Force Level
Powerhead LEDs
ROUND LED
LONG LED
LED indicator colors:
 OFF
 Blue
 Purple
 Red
Force Level 1
BLUE
BLUE
BLUE
BLUE
 
Off
Off
Off
Off
 
 
Force Level 3
 
 
Force Level 4
PURPLE
PURPLE
PURPLE
PURPLE
 
 
 
Off
 
 
 
Force Level 6
 
 
Force Level 7
RED
RED
RED
RED
 
 
Off
 
 
 
Force Level 9
 
 
 
Force Level 2
Force Level 5
Force Level 7
 
 
PROGRAM
SET
 
PROGRAM
SET
 
The Current 
UP FORCE SETTING 
will display. SEE CHART IN NEXT 
COLUMN.
 
Action
 LED Indication/Result
Press and hold
both up and 
down buttons
2 seconds or until round
LED turns RED.
Press either
until you reach
desired setting.
Press and 
release.
Press either 
until you
reach the 
desired setting.
Press and 
release.
USE CHART IN NEXT COLUMN
USE CHART IN 
NEXT COLUMN
LOCKS IN SETTING.
Then the New
DOWN FORCE
SETTING will display.
OFF
RED
OFF
BLUE
Flashes 3 Times
BLUE
Flashing
OFF
BLUE
BLUE
LOCKS IN SETTING.
Both LEDs turn
BLUE then OFF
confirms both 
FORCE Settings are reset.
BLUE
BLUE
OFF
OFF
FORCE SETTINGS DONE
1
2
3
4
5