STEP 9 – ELECTRICAL SYSTEM 
Country Flame’s Smart Fireplace Furnace comes standard with two blowers each rated to 
move 525 cubic feet of room air per minute.   The blower system includes all necessary 
parts, except some additional wire, required for a local certified electrician to install the 
blowers, speed controls, and the thermostat.  The fireplace’s electrical system SHOULD 
BE tested before final brickwork is completed.  If electrical testing is not done, access to installed 
wiring may be limited or worse, not repairable without costly removal of brickwork.  Request that 
the local electrician make sure all blowers, air discharge snap disc, and rheostats are properly 
working before completing the brickwork. 
 
FIGURE 12:  THERMAL SNAP DISK LOCATION 
 
FIGURE 12 shows the location of the thermal snap disk on the right side behind the front grille.  
Service to this component should only be accomplished by a qualified technician.  This snap disk 
comes pre-wired from the factory.  Once connected to the main power circuit, this snap disk will 
automatically turn the blower system on and off as the Smart Fireplace Furnace reaches either the 
appropriate hot or cold temperature. 
 
 
FIGURE 13:  ELECTRICAL JUNCTION BOX 
 
FIGURE 13 shows the location of the electrical junction box cover.  A certified electrician should 
remove the cover of this junction box to connect the Smart Fireplace Furnace’s blower system to 
the household electrical grid and the supplied thermostat with proper temperature rated romex 
wire.  
WARNING:   
Failure to properly wire in the blower system can lead to shock hazard, a 
malfunctioning blower system, or could create a fire hazard.  Contact a certified electrician to 
ensure proper installation of the Smart Fireplace Furnace blower system.  NOTE:  All wiring 
should be completed before masonry work is complete. 
 
Version 7.1 
20