clear of sharp objects.  Further, ensure that the power cables or motor leads are not kinked.  Never 
allow the power cables or motor leads to come in contact with oil, grease, hot surfaces, or 
chemicals.  Utilize the two high temperature wires (red and white) provided by Country Flame to 
connect the air discharge snap disc to the electrical system as shown in FIGURE 14.  Use the high 
temperature wire (green/yellow) to ground the fireplace to the right blower box.  The 
green/yellow wire installed by Country Flame at the factory should be connected to one of the 
screws used to hold the air discharge snap disc to the fireplace.  Connect the other end of the 
green/yellow wire to the right blower box or another earth ground coming from the circuit 
breaker box.  The installing electrician should ensure proper grounding is accomplished for both 
blower boxes and the fireplace unit as per FIGURE 14.  Screws and wire nuts are provided by 
Country Flame to ensure all parts are available during installation. 
 
High temperature blower motor systems are lubricated at the factory and should require no further 
lubrication; however, at higher inlet temperatures, increased bearing life can be achieved by 
annually re-lubricating the motors with 10 to 20 drops of Anderol Number 465 high temperature 
synthetic lubricant.  DO NOT USE petroleum-based oil, as bearing failure will result. 