New Buck Corporation 384 Manual De Usuario

Descargar
Página de 54
SECTION V 
ZERO CLEARANCE INSTALLATION OF 
MODEL 384 (ZC) 
 
    The installation must conform with local codes, or in the absence of local codes, with the 
       National Fuel Gas Code, ANSI Z223.1/NFPA54. 
   This appliance may be installed in an After-Market
Manufactured (Mobile) Home, 
      where not prohibited by state or local codes. 
*  (After Market:  Completion of sale, not for the purpose of resale from the manufacturer). 
 
This appliance is only for use with the type of gas indicated on the rating plate.  This appliance 
is not convertible for use with other gases. 
 
NOTE:      See “Producing Adequate Ventilation” page 31. 
 
CHOOSING THE LOCATION FOR YOUR FIREPLACE:  
The figure below shows some of the many ways your fireplace may be installed.  Consider the 
traffic pattern in your room and the location of doors and windows.  Moving air from ceiling 
fans, open doors, and hot air grills may cause the flames to soot.  If a disturbance is found that 
affects the flames, it must be eliminated by turning off the ceiling fan, closing the door, or 
closing or moving the hot air register.  A corner location may be best where space is limited. 
 
Your fireplace weighs no more than some of your fine furniture.  If the fireplace is located near 
a load bearing wall, additional supports to the foundation will not be necessary.  HEAVY 
FACINGS, SUCH AS BRICK, STONE, ETC.,  MAY REQUIRE ADDITIONAL 
FOUNDATION SUPPORT. 
 
NOTE: If this appliance is installed directly on carpeting, tile or other combustible 
material, other than wood flooring, the appliance shall be installed on a metal or wood 
panel extending the full width and depth of the appliance. 
 
The Manufacturers Trim Kit must be used for Zero Clearance Installation. 
 
1. Set the top (long) trim panel in place on top of unit.  The panel should be flat against the 
outside face of the fireplace, and standing vertically (measuring approximately 12” from the 
rear of the unit to the front area).  Mark along the lower edge of  the trim panel with a pencil to 
make reference line for mounting.
 
 
2.  Set the side panels in place, flat against the fireplace.  Mark down the inside edge of the trim 
panel to make a vertical reference line. 
 
GAS LINE 
The gas supply line and electrical supply must 
be installed before framing in the fireplace by a 
licensed  installer. 
 
DRAFTS 
Do not locate the fireplace in high traffic areas 
or areas exposed to high drafts and winds.  
Locate the fireplace away from furniture and 
draperies. 
ROOM DIVIDER
PARTIAL ROOM PROJECTION
FU
L
L
 R
OOM
 P
R
OJE
C
TION
FLUSH
CORNER
Page 24