WARNING: Installation and repairs should be 
performed by a qualified service person.  The appli-
ance should be inspected before use and at least an-
nually by a professional service person. More fre-
quent cleaning may be required due to excessive lint 
from carpeting, bedding material, pet hair, etc. It is 
imperative that control compartments, burners and 
circulating air passageways of the appliance be kept 
clean.
 
FIREPLACE CLEARANCES 
The fireplace may be placed directly on a combustible 
floor, against a combustible wall   at marked clear-
ances, or on a raised wooden platform. 
If the fireplace is to be installed on a raised wooden 
platform, the platform must be a continuous level 
surface.  The fireplace must be secured in place so it 
cannot shift positions.  Only the header (see below) 
may rest on the standoffs on top of the firebox. 
When the firebox is installed over carpeting, vinyl tile, 
or any combustible material other than wood flooring, 
it must be installed on a metal or wood panel 
extending its full width and depth.  Alternatively, the 
carpeting, vinyl tile, etc. may be removed beneath the 
fireplace before installing.
 
 
COMBUSTIBLE MATERIALS MUST NOT BE 
INSTALLED OVER OR TOUCH ANY BLACK 
PAINTED SURFACE.  DO NOT BLOCK HEAT 
CIRCULATING AIR OUTLETS.  DOING SO MAY 
RESULT IN POTENTIAL FIRE HAZARDS
1. Sidewall Clearances:  Clearances from the side 
of the fireplace opening to any adjacent 
 
 
 
combustible wall should not be less than  7"right 
side and 7" left side. 
2.  Ceiling Clearances:  The ceiling height   
should not  be less than 26" from the top of   
the fireplace opening. 
This list of specific instructions will help you make 
certain that every installation operation is 
performed correctly.  Complete the installation 
steps in the sequence shown. 
LOCAL BUILDING CODES SHOULD BE 
CONSULTED IN ALL CASES AS TO THE 
PARTICULAR REQUIREMENTS CONCERNING THE 
INSTALLATION OF FACTORY BUILT FIREPLACES. 
 
Select the location for the fireplace by taking into 
consideration the factors previously outlined in the 
“Choosing the Location.”  
Framing the Firebox 
The width of the framed opening must be 35-
17/32".  The height of the framed opening must be 
25 1/8".   For depth of opening see side view of this 
page. 
The entire fireplace can  be elevated above the floor 
to achieve a raised hearth effect.  This can be done 
by adding a small platform to achieve the desired 
height.   
NOTE:  The wiring for the blower must be 
installed during the framing stage.  Insulation 
should be used in the framing on the back, sides, 
and top.   
Install the Firebox 
Install the firebox into the framed  opening by 
placing it directly in front of the opening and sliding 
it into the proper position.  Please follow wooden 
surround instructions.(Also see page 25) 
 
INSTALLING THE FIREBOX 
Level the Firebox 
Check the level of the firebox on the top edge of the 
fireplace face.  Shim if necessary.
 
SIDE 
VIEW 
25-1/8” 
FRAMING 
HEADER 
FRONT 
VIEW 
     
 
 
13-3/4” 
 