Regency P33-3 Zero Clearance Direct Vent Gas Fireplace
Diagram 1
Diagram 3
STANDARD FLUSH 
DOOR
The standard fl ush door comes with a black 
frame. To install the frame, simply hook the top 
door fl ange onto the top of the unit and swing 
the door towards the unit, diagram 1. Be care-
ful that the glass gasket does not roll up; there 
must be a gap between the gasket and the door 
lip to ensure that the door sits securely on the 
unit. Diagram 2.
Diagram 2
INSTALLATION
5th Grate Tab
6)  Place the bottom left front edge of Log 251 
against the left edge of  the burner tray and 
rest the log on the cutout on Log 
 253.
7)  Position Log 252 across the cutouts in  Logs 
254 and 253. The notch in the bottom right 
end fi tting against the 5th grate tab.
8)  Pull off ember size pieces of rockwool and 
gently place them on the front of the burner 
tray in the places shown in the photo below. Do 
not compress the rockwool, leave it loose.
Place rockwool in these 2 locations 
on the burner tray.
251
252
250
254
253
250
254
253
251
253
250
254
253
254
252
Cutout
9)  Test fi re to ensure proper light off (make 
sure fl ame fl ows smoothly from one end of 
burner to the other).  If there is any fl ame 
hesitation, check that area for any blockage 
of the burner ports.   
10) Install fl ush glass and bay glass (if used) as 
Use the hook to pull the spring out until you 
can put the hook into the slot on the bottom 
door bracket. Repeat for 2nd spring. See 
diagram 3.
 
To remove the fl ush door, reverse the above 
steps.
Optional Flush Trim
Attach the round magnets to the back of the top 
trim piece and to the bottom trim piece, then at-
tach trim to the top and bottom of Flush door.