 P90 Zero Clearance Direct Vent Gas Fireplace
18
The P90 is approved for a maximum 40 ft. straight vertical, with rigid pipe 
4" x 6-5/8" vent systems for Propane and Natural Gas, as per diagram.
The shaded area in the diagram show all allowable combinations of straight 
vertical and offset to vertical terminations with rigid pipe vent systems for 
Propane and Natural Gas. Maximum two 45
o
 elbows allowed.
•   Vent must be supported at offsets
•   Firestops are required at each fl oor level and whenever passing 
through a wall.
•   Maintain clearances to combustibles as listed in the "Clearances" 
section.
INSTALLATION
Please note that all vertical 
measurements are taken from 
the base of the unit excluding 
risers or bottom stand-offs.