CarAlarms.com P90-NG1 Manual De Usuario

Descargar
Página de 48
Excalibur
®
 P90 Zero Clearance Direct Vent Gas Fireplace
19
INSTALLATION
Horizontal Venting with Two (2) 90
o
 Elbows
Horizontal Venting with Three (3) 90
o
 Elbows
One 90
o
 elbow = Two 45
o
 elbows.
 Option      V 
         H + H1
     A) 
6"  Min.       2' Max.
     B) 
1'  Min.       3' Max.
     C) 
2'  Min.       4' Max.
     D) 
3'  Min.       5' Max.
     E) 
4'  Min.       6' Max.
     F) 
5'  Min.       7' Max. 
     G) 
6' Min.       8' Max.
W i t h   t h e s e   o p t i o n s , 
maximum total pipe length 
is 30 feet with minimum 
of 6 feet total vertical 
and maximum 8 feet total 
horizontal.
Please note minimum 1 
foot between 90
o
 elbows 
Must Use: 5" x 8" Simpson Direct Vent GS Piping with FPI Increaser 
Starter Collar (Part #946-605).
Must Use: 5" x 8" Simpson Direct Vent GS Piping with FPI 
Increaser Starter Collar (Part #946-605).
One 90
o
 elbow = Two 45
o
 elbows.
Option      V 
  H          V + V1   H + H1
     A) 
6" Min.  1' Max.  1'6" Min.  2' Max.
     B) 
1' Min.  2' Max.  3' Min.    3' Max.
     C) 
2' Min.  2' Max.  5' Min.   4' Max.
     D) 
3' Min.  2' Max.  7' Min.    5' Max.
     E) 
4' Min.  3 Max.  9' Min.   6' Max.
     F) 
5' Min.  4' Max.  10' Min.  7' Max.
     G) 
6' Min.  5' Max.  11' Min.   8' Max.
     H) 
7' Min.  6' Max.  12' Min.   9' Max.
With these options, 
max. total pipe length 
is 30 feet with min. of 
12 feet total vertical 
and max. 9 feet total 
horizontal.
Please note min. 1 
foot between 90
o
elbows is required.