Desa (V)KC42PE Manual De Usuario

Descargar
Página de 40
www.desatech.com
116240-01E
31
vENTING SYSTEM
Conduct annual inspection of the venting system 
following these guidelines:
1.  Check areas of venting system that are exposed 
to the weather for corrosion (rust spots or streaks 
and, in extreme cases, holes). Have these items 
replaced immediately by a qualified service 
person.
CLEANING AND 
MAINTENANCE
Continued
2.  Remove the vent cap and shine a flashlight 
into the vent. Remove any foreign material.
3.  Check for evidence of excessive condensation. 
Continuous condensation can cause corrosion 
of caps, pipes and fittings and can be caused 
by having excessive lateral runs, too many 
elbows or exterior portions of the system being 
exposed to cold weather.
4.  Inspect joints to verify that no pipe section or 
fitting has been disturbed and loosened. Check 
mechanical supports such as wall straps for 
rigidity.
TROUbLEShOOTING
 WARNING: Turn off heater and let cool before servicing. Only a 
qualified service person should service and repair heater.
 CAUTION: Never use a wire, needle or similar object to clean 
pilot. This can damage pilot unit.
Note: 
All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. No  gas  supply  or  shutoff 
valve is OFF
2. Air in gas line
3. Construction debris clogging 
pilot orifice
4. Low gas pressure
5. Kinked pilot line
6. Control valve is not opening
7. No power to unit or the igni-
tion module or power trans-
former is bad
REMEDY
1. Check to see if you have gas 
supply  and  that  equipment 
shutoff valve is opened
2. Repeat  lighting  procedure 
several times to purge all air 
out of lines. If after repeated 
attempts appliance does not 
light, call for qualified service 
and repair
3. Remove debris and dirt, in-
spect  and  clean  any  other 
possible obstructions
4. Contact your gas supplier to 
check pressure
5. Have  a  qualified  technician 
replace pilot line
6. Replace control valve (Refer to 
Replacement Parts, page 34)
7. Check  that  main  power  is 
on and that all wire connec-
tions  are  made  correctly  to 
the ignition model (see Wiring 
Diagram, page 27). Check for 
24 VAC at the secondary side 
of the transformer. If 24 VAC 
is present and the module does 
not operate, have the module 
replaced otherwise have the 
transformer replaced
OBSERVED PROBLEM
Ignitor  will  not  spark  or  pilot 
will not light