Sanyo KHS1852-S Manual De Usuario

Descargar
Página de 98
55
9-2. Air conditioner does not operate.
9-2-1. Circuit breaker trips (or fuse blows).
A.  When the circuit breaker is set to ON, it is tripped soon. (Resetting is not possible.)
There is a possibility of ground fault.
Check insulation resistance.
If resistance value is 2M
½
or less, insulation is defective (“NO”).
Measure insulation
resistance of electrical
parts in outdoor unit.
NO
NO
Set circuit breaker to OFF.
Measure insulation
resistance of electrical
parts in indoor unit.
1
Remove both power supply wires 
and inter-unit wires from terminal 
plate in outdoor unit.
Measure insulation resistance
of outdoor unit.
•  
2
Remove inter-unit wires from 
terminal plate in indoor unit.
Measure insulation resistance
of indoor unit.
•  
•  
•  
Insulation of 
outdoor unit 
is defective.
Insulation of 
indoor unit 
is defective.
WARNING
1
1
2
8
7
2
3
3
4
4
5
5
6
6
G
G
Indoor
unit
2
Outdoor
unit
1
1
Inter–unit
wiring
Power supply
wiring
Circuit 
breaker
Power 
supply
Ground
G
L2
L1
000-111 
SM 
(18-68) 
 
00.3.17 
11:49 
AM 
  y [ W  55