installation
 Fitting the Coaxial Flue 
 
(Ø 60 / 100 Vertical)
 Note: See table for maximum and minimum fl ue runs.
Contents:
1x Conical Adaptor (60/100mm)
1x Vertical Flue Kit (80/125mm)
The vertical fl ue kit is supplied with a specially designed weather 
proof terminal fi tted, it can be used either with a fl at roof or a 
pitched roof.
The Vertical fl ue kits useable lengths with the pitched roof 
fl ashings are indicated in Fig. 7.
Before proceeding to fi t the fl ue, ensure that the maximum fl ue 
length has not been exceeded (See the tables) and that all elbows 
and bends have been taken into consideration, for each additional 
90° elbow 1 metre must be subtracted from the total fl ue length, 
and for each 45° 0.5 metres must be subtracted from the total fl ue 
length (the height of the vertical adaptor and a 45° bend can be 
seen in Fig. 8).
Mark the position of the fl ue hole in the ceiling and/or roof (see 
Fig. 7 for distance from wall to the centre of the fl ue).
Cut a 130mm diameter hole through the ceiling and/or roof and 
fi t the fl ashing plate to the roof.
DO NOT cut the vertical fl ue kit.
To connect the vertical fl ue kit directly to the boiler, place the 
vertical starter kit (Part No. 3318079) (see Fig. 7) onto the exhaust 
manifold and secure with the clamp, fi t the vertical adaptor onto 
the vertical starter kit (note: there is no need to use a clamp to 
secure this as it is a push fi t connection), the vertical fl ue kit must 
then be inserted through the roof fl ashing, this will ensure that 
the correct clearance above the roof is provided as the terminal 
is a fi xed height.
Should extensions be required, they are available in 1 metre 
(Part No. 3318077), 500mm (Part No. 3318078) and they must be 
connected directly to the vertical starter kit before connecting the 
adaptor to allow the vertical fl ue kit to be fi tted.  In the event that 
extension pieces need to be shortened, they must  only be cut at 
the male end and it must be ensured that the inner and outer fl ue 
remain fl ush.
 
When utilising the vertical fl ue system, action must be taken to 
ensure that the fl ue is supported adequately to prevent the weight 
being transferred to the appliance fl ue connection by using 1 fl ue 
bracket per extension.
When the fl ue passes through a ceiling or wooden fl oor,  there 
must be an air gap of 25mm between any part of the fl ue 
system and any combustible material.  The use of a ceiling plate 
will facilitate this.  Also when the fl ue passes from one room to 
another a fi re stop must be fi tted to prevent the passage of smoke 
or fi re, irrespective of the structural material through which the 
fl ue passes.
180 mm
Vert Adaptor
(supplied with flue kit)
Vertical Starter
Part No: 3318079
* This length will vary
   according to the type
   of flashing installed
Total length
of Vertical Kit
1355 mm
Useable length
of Vertical flue
690 mm*
Fig. 7
Fig. 8