Series 24 Specifications
 
 
 
 
 
 
 
BURNER  
HEATING   
 
 
WATER  
BOILER WEIGHT
 
 
 
 
  NET I=B=R RATING   
INPUT 
SURFACE 
NET 
 PRESSURE 
CONTENT 
w/ WATER 
 
 
 
GROSS 
 
 
 
 
 
(SQ. FT.)   
FIREBOX 
IN 
(GAL.) 
(LBS.) 
VENT
  BOILER 
HORSE-  OUTPUT 
SQ. FT. 
MBH 
MBH 
OIL 
GAS 
 
 
VOLUME  FIREBOX 
 
 
 
 
DIA.
  MODEL 
POWER 
(MBH) 
STEAM 
STEAM 
WATER 
(GPH) 
(MBH) 
STEAM 
WATER 
(CU. FT.)  (“W.C.”) 
STEAM 
WATER 
STEAM 
WATER 
(IN.)
  24-03 
10.2 
342 
1071 
257 
297 
3.05 
438 
34.2 
37.0 
3.2 
.33 
44.5 
66.0 
1439 
1618 
7
  24-04 
14.1 
471 
1471 
353 
410 
4.10 
594 
48.6 
54.3 
4.8 
.38 
53.0 
75.0 
1811 
1995 
7
  24-05 
18.9 
634 
1983 
476 
551 
5.50 
792 
63.0 
71.5 
6.4 
.31 
61.5 
84.0 
2184 
2372 
8
  24-06 
23.8 
797 
2492 
598 
693 
6.90 
990 
77.5 
88.8 
7.9 
.38 
70.0 
93.0 
2557 
2749 
8
  24-07 
28.0 
937 
2929 
703 
815 
8.10 
1174 
91.9 
106.0 
9.5 
.36 
78.5 
102.0 
2930 
3126 
8
  24-08 
32.5 
1087 
3396 
815 
945 
9.40 
1358 
106.3 
123.3 
11.0 
.35 
87.0 
111.0 
3303 
3503 
10
  24-09 
39.3 
1316 
4146 
995 
1148 
11.40 
1641 
120.7 
140.5 
12.6 
.35 
95.5 
120.0 
3676 
3880 
10
  24-10 
45.0 
1505 
4788 
1149 
1309 
13.00 
1867 
135.1 
157.8 
14.2 
.40 
104.0 
129.0 
4048 
4257 
10
  24-11 
50.5 
1690 
5429 
1303 
1470 
14.60 
2093 
149.5 
175.0 
15.7 
.45 
112.5 
138.0 
4421 
4634 
12
  24-12 
55.3 
1852 
5983 
1436 
1610 
16.00 
2320 
164.0 
192.3 
17.3 
.49 
121.0 
147.0 
4794 
5011 
12
Since 1949, homeowners have depended on us  
for quality, value and service.
3633 I Street, P.O. Box 14818 
Philadelphia, PA 19134
Phone: (215) 535-8900  Fax: (215) 535-9736
www.crownboiler.com
Commercial Hot Water or Steam Boiler
Commercial Hot Water or Steam Boiler
Beckett Gas Burners 
(Natural Gas)
 
 
 
 
 
 
Min. Inlet 
Gas  
 
Boiler 
Burner 
 Rate 
STD. Motor  
 
Pressure   
Train  
 
Model 
Model 
Control 
Voltage 
H.P. 
(in W.C.) 
Size
 
24-03 
CG10.1S 
On/Off 
120/60/1 
1/3 
3.2 
1”
 
24-04 
CG10.4S 
On/Off 
120/60/1 
1/3 
3.6 
1”
 
24-05 
CG10.5S 
On/Off 
120/60/1 
1/3 
4.3 
1-1/4”
 
24-06 
CG10.6S 
On/Off 
120/60/1 
1/3 
4.4 
1-1/2”
 
24-07 
CG15.3S 
Lo/Hi/Lo 
120/60/1 
1/2 
4.0 
1-1/2”
 
24-08 
CG15.4S 
Lo/Hi/Lo 
120/60/1 
1/2 
4.4 
1-1/2”
 
24-09 
CG25.2S 
Lo/Hi/Lo 
120/60/1 
3/4 
4.3 
1-1/2”
 
24-10 
CG25.3S 
Lo/Hi/Lo 
120/60/1 
3/4 
4.9 
1-1/2”
 
24-11 
 CG25.4S 
Lo/Hi/Lo 
120/60/1 
3/4 
4.9 
1-1/2”
 
24-12 
CG50.2S 
Lo/Hi/Lo 
208-240/60/1 
3.9 
1-1/2”
Minimum gas pressures shown are for standard burners only.
See manual for minimum gas pressure when other size gas trains are used.
Beckett Oil Burners 
 
Boiler 
Burner 
 Rate 
STD. Motor  
 
 
Model 
Model 
Control 
Voltage 
H.P.
  24-03 
CF500 
On/Off 
120/60/1 
1/3
  24-04 
CF800 
On/Off 
120/60/1 
1/3
  24-05 
CF800 
On/Off 
120/60/1 
1/3
  24-06 
CF1400 
Lo/Hi/Lo 
120/60/1 
1/2
  24-07 
CF1400 
Lo/Hi/Lo 
120/60/1 
1/2
  24-08 
CF1400 
Lo/Hi/Lo 
120/60/1 
1/2
  24-09 
CF2300A 
Lo/Hi/Lo 
120/60/1 
3/4
  24-10 
CF2300A 
Lo/Hi/Lo 
120/60/1 
3/4
 
24-11 
CF2500 
Lo/Hi/Lo 
240/60/1 
2
  24-12 
CF2500 
Lo/Hi/Lo 
240/60/1 
2
S24-12/05 (25M)
PN980521
AVAILABLE FROM
Notes:
1.   Trim suffix 
S = Steam Boiler 
W = Water Boiler 
Fuel suffix 
N = Natural Gas 
O = Oil
2.  I=B=R net ratings shown are based on piping and pick-up allowances which vary from 1.333 to 1.289 for steam and 1.15 for water.  Consult manufacturer for installations having unusual piping and pick-up 
requirements, such as intermittent system operation, extensive piping systems, etc.  The I=B=R burner capacity in GPH is based on oil having a heat value of 140,000 BTU per gallon.
3. Firebox volume does not include added volume of 8” extended burner mounting plate (BMP).  If 8” BMP is specified (refer to Figure 1), add 0.7 cu. ft. to volume listed above.
4.  Boiler ratings are based on 12.5% CO2 (oil) and 9.7% CO2 (natural gas), + .10” (inches) water column pressure at boiler flue outlet.   Ratings shown above apply at altitudes up to 1000 feet on oil and 2,000 
feet on gas. For altitudes above those indicated, the ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
Maximum Allowable Working Pressure:  Steam Boiler – 15 PSI, Water Boiler – 50 PSI 
Standard Safety (Relief) Valve Set Pressure:  Steam Boiler – 15 PSI, Water Boiler – 30 PSI