ALTERNATE FLOOR PROTECTION
All floor protection materials must be non-combustible ie. metal,
brick, stone, mineral fiber boards). Any combustible material
may not be used.
The easiest means of determining if a proposed alternate floor
material meets requirements listed in this manual is to follow this
procedure.
R-value = thermal resistance
k-value = thermal conductivity
C-value = thermal conductance
1. Convert the specification to R-value;
a. If R-value is given, no conversion is
needed.
b. If k-value is given with a required
thickness (T) in inches: R=1/k X T.
c. If C-value is given: R=1/C.
2. Determine the R-value of the proposed alternate
floor protector.
a. Use the formula in Step 1 to convert
values not expressed as R.
b. For multiple layers, add R-values of each
layer to determine overall R-value.
3. If the overall R-value of the sustem is greater
than the R-value of the specified floor protector,
the alternate is acceptable.
EXAMPLE:
The specified floor protector should be 3/4 thick material with a
k-factor of 0.84. The proposed alternate is 4 brick with a C-
factor of 1.25 over
1/8 mineral board witha k-factor of 0.29.
Step A. Use formula above to convert specifications to R-value.
R=1/k X T= 1/.84 X .75 = .893
Step B. Calculate R of proposed system.
4 brick of C-1.25, therefore
R brick = 1/C = 1/1.25 = 0.80.
1/8 mineral board of k = 0.29 therefore
R mineral board = 1/.29 X 0.125 = 0.431
Total R = R brick + R mineral board=
0.8 + 0.431=1.231
Step C. Compare proposed system R = 1.231 to specified R of
0.893. Since R is greater than required, the system is acceptable.
Definitions:
Thermal conductance =
C = Btu = W
(hr)(ft
2
)(F) (m
2
)(K)
Thermal conductivity =
k =
Btu = W = (Btu)
(hr)(ft
2
)(F) (m
2
)(K) (hr)(ft)(F)
Thermal resistance =
R =
Btu = (m
2
)(K) = (Btu)(inch)
(hr)(ft
2
)(F) W (hr)(ft
2
)(F)
FOR THE JØTUL F 3 CB WOOD STOVE REQUIRES
FLOOR PROTECTION WITH A MINIMUM INSULATING
R VALUE OF 1.1.
ALCOVE INSTALLATION REQUIRE A MINIMUM R VALUE
OF 1.1. (IF A UL/ULC or WHI LISTED HEARTH PAD IS NOT
USED.)
APPENDIX A:
20
F 3 CB PARTS LIST
2
Inner rear heatshield
2B
Outer rear heatshield
6
Smoke outlet cover
7
Traverse bar
8
Top plate with smoke cover
11
Baffle plate
12
Air distributor
15
Back plate
22
Side plate
23
Back burn plate
24
Right burn plate
26
Air deflector
28
Sliding air vent
29
Front plate
31
Log retainer
35
Door
37
Hinge pin
40
Start-up air vent
42
Door handle complete
43
Locking bar
45
Glass
46
Sparkscreen
51
Ashlip
52
Leg
55
Bottom plate
57
Inner bottom plate
59
Left burn plate
62
Secondary air cover
64
Flat ash housing gasket
65
Ash housing
70
Ashpan
76
Ashpan door
73
Stove tool
78
Door latch
79
Bottom heatshield
ONLY USE REPLACEMENTS PARTS