Drolet ECO-45 Manual De Usuario

Descargar
Página de 29
FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED 
CAN RESULT IN POOR PERFORMANCE AND SAFETY HAZARDS. 
NEVER CLEAN WHEN HOT. 
 
NOTE:  Inspect burn pot periodically to see that holes have not 
become plugged. If so, clean thoroughly. 
 
ASH REMOVAL 
 
Ashes should be placed in a metal container with a tight-fitting lid. 
The closed container or ashes should be placed on a noncombustible 
surface or on the ground, well away from all combustible materials 
pending final disposal. If ashes are disposed of by soil burial or 
otherwise locally dispersed, they should be retained in the closed 
container until all cinders have thoroughly cooled. 
 
ASH DISPOSAL  
 
The ECO-45 has an ash bin located below the firebox. To remove 
ashes: 
 
a. 
Make sure fire is out and the firebox is cool.
 
 
b. 
Open the door and remove the baffle from the firebox. Close the 
door.
 
 
c. 
With the door closed, clean heat exchanger tubes by activating 
the cleaning rod back and forth from front to back. 
(see Cleaning section and Figure 18 & 19) . 
 
d.  Open the door and remove the burn pot by grasping it and 
pulling straight out. Scrape the burn pot with a scraper if 
necessary. Make sure that the burn pot holes are not plugged. 
Empty ashes from the burn pot into the pedestal ash bin through 
the opening at the bottom of the firebox. Put the burn pot back in 
place. Make sure it is level and pushed all the way in. 
 
e.  Scrape the ashes in the firebox into the pedestal ash bin 
through the opening or the bottom of the firebox or vacuum to 
remove ashes. 
 
WARNING: Make sure ashes are cool to the touch   
before using a vacuum. 
See “VACUUM USE”. 
 
f. 
Periodically remove and empty the ash bin (see Figure 20) by 
opening the front lid of the pedestal below the ash lip. Dispose 
of ashes properly. 
        (See “ASH REMOVAL” above) 
 
g. 
Put the ash bin back into place, making sure that you tighten the 
knob and maintain a good seal.  Inspect gasket at the same 
time to make sure it is in good condition. 
HIGH TEMPERATURE
SWITCH L-250
MANUAL RESET
HIGH TEMPERATURE
SWITCH L-250 AUTOMAT
HIGH TEMPERATURE
SWITCH F-160
CONTROL
AIR SUPPLY
CONVECTION
BLOWER
 
 
 
 
 
 
CLEANING
ROD
 
 
 
 
 
 
 
 
 
 
FIGURE 21 
Side view 
MAINTENANCE
16 
FIGURE 18 
Baffle removal 
FIGURE 19 
Cleaning rod 
FIGURE 20 
Ash drawer